CAI re-certification for our Twin Digital Satellite Coaxial Cable!

CAI re-certification for our Twin Digital Satellite Coaxial Cable!

We are delighted to announce that our 2XCB63 has recently passed the CAI benchmark test for the eighth time with the same cable design and manufacturer. This cable is now certified for another 18months and has been regularly tested and passed for a 11 and a half year period! Quite an achievement and the only cable still standing from the start of the benchmark process! First to pass and last original one standing. The test is independently checked and verified with random collection by the CAI. We are proud of this success!

Size Guide

Size Guide

Accessories
Cable Size (mm)Cable CoresP Clips SizeRSFJ Double Clips SizeGlands
1.02+EAC7302251
1.52+EAC8342251
2.52+EAC11382251
4.02+EAC12362252
1.03+EAC9342251
1.53+EAC9342251
2.53+EAC11422252
4.03+EAC13TBA254
1.04+EAC9382251
1.54+EAC9382251
2.54+EAC12422252
4.04+EAC14TBA254
1.07+EAC11422251
1.57+EAC12422252
2.57+EAC13TBA254
1.512+EAC14632254
2.512+EAC20TBA255
1.519+EAC16702255
2.519+EAC23TBATBA

Certified to Low Voltage Directive (LVD) 2006/95/EC

Contains NO HALOGENS essential for use with LSZH Fire Cable.

Available in the following colours: black, red & white with any other colour available for manufacture.

“AC”clips packed in 100`s “rsfj”double clips packed in 50`s glands packed in 100`s

Prefix to product code for ordering purposes.

Carriage paid on all orders over £250.00 nett value.

Flame retardant glands red also available on request
Locknuts for glands charged extra m20 locknuts
30150 the recommended stripping tool
T3964 cable cutter for o.D. 50.0mm or 14.0mm max
Cable Shrouds

Cable Shrouds

Features 

  • LSF cable shroud
  • Low smoke and fume
  • Fire resistant
  • Colours: Red, White & Black
  • Packaging – Packet of 10

Shrouds

Cable Size (mm)Cable CoresShroud
1.02+ESH20
1.52+ESH20
2.52+ESH20
4.02+ESH20
1.03+ESH20
1.53+ESH20
2.53+ESH20
4.03+ESH20
1.04+ESH20
1.54+ESH20
2.54+ESH20
4.04+ESH20
1.07+ESH20
1.57+ESH20
2.57+ESH20
1.512+ESH20
2.512+ESH20
1.519+ESH20
2.519+ESH20

Cable Glands

Cable Glands

Features 

  • Halogen free
  • IP68
  • Comply with BSEN 50262: 1999
  • Resistant to corrosion
  • Low smoke and fume
  • Fire resistant
  • Colours: Red, White & Black
  • Packaging – Packet of 100

Fire Cable Gland Sizing

Cable Size (mm)Cable CoresGlands
1.02+E251
1.52+E251
2.52+E251
4.02+E252
1.03+E251
1.53+E251
2.53+E252
4.03+E254
1.04+E251
1.54+E251
2.54+E252
4.04+E254
1.07+E251
1.57+E252
2.57+E254
1.512+E254
2.512+E255
1.519+E255
2.519+ETBA

LSF P Clips

LSF P Clips

Features 

  • Halogen free
  • Resistant to corrosion
  • Low smoke and fume
  • Fire resistant
  • Colours: Red, White & Black
  • Material – Copper
  • Packaging – Box of 100

P Clip Sizes

Cable Size (mm)Cable CoresP Clips Size
1.02+EAC7
1.52+EAC8
2.52+EAC11
4.02+EAC12
1.03+EAC9
1.53+EAC9
2.53+EAC11
4.03+EAC13
1.04+EAC9
1.54+EAC9
2.54+EAC12
4.04+EAC14
1.07+EAC11
1.57+EAC12
2.57+EAC13
1.512+EAC14
2.512+EAC20
1.519+EAC16
2.519+EAC23

LSF P Clips

Double P Clips

Features 

  • Halogen free
  • Resistant to corrosion
  • Low smoke and fume
  • Fire resistant
  • Colours: Red, White & Black
  • Material – Copper
  • Packaging – Box of 50

Accessories

Cable Size (mm)Cable CoresRSFJ Double Clips Size
1.02+E302
1.52+E342
2.52+E382
4.02+E362
1.03+E342
1.53+E342
2.53+E422
4.03+ETBA
1.04+E382
1.54+E382
2.54+E422
4.04+ETBA
1.07+E422
1.57+E422
2.57+ETBA
1.512+E632
2.512+ETBA
1.519+E702
2.519+ETBA

Cable Strippers

Cable Strippers

CBL Cable Stripper

The CBL cable stripper is perfect to use with our range of fire performance cables, its simple and easy to use design makes stripping cable very quick and easy

Features 

  • secure grip achieved by introducing soft padding for non-slip grips,
  • new locking mechanism prevents the unwanted opening of the tool,
  • absolutely straightforward longitudinal cuts – with innovative internal cable duct,
  • redesigned blade layout and intake to stop cable waste from jamming the tool,
  • no cutting depth adjustments required,
  • the special outlined blades allow the effortless stripping of solid and stranded wires of diameters 0.2 – 0.3 – 0.8 – 1.5 – 2.5 – 4.0 mm²,
  • blades with special Titanium-Nitride coating (TIN) to achieve longer life, faster cutting and less wear,
  • with integrated, mulit-function, slide-out blade,
  • Durable and ergonomically designed pocket clip,
  • this tool is the ideal choice for working in cable junctions or connector boxes,
  • TÜV / GS approved
The Versatility of LISTEC

The Versatility of LISTEC

Listec is a very versatile and robust heat detection system. Due to its design and construction Listec can operate and thrive in many different environments and settings. Below are some of the many settings where Listec thrives.

 

 

 

 

 

 

 

 

 

Blackwall Tunnel

Blackwall Tunnel

Blackwall Tunnel

Location: South, East London

Contract Value: £120,000

Cables Britain have successfully designed, commissioned and supplied an addressable and fully redundant heat detection system (Listec sec 20) for the Blackwall tunnel in South East London

Universal Connection Module UCM 15

Universal Connection Module UCM 15

UNIVERSAL CONNECTION MODULE UCM 15

Universal connection module for CBO 15-SEC and CBO 15-ESD to connect up to two sensor cables SEC 15

General data

  •  Universal connection module UCM 15-SEC for connection box CBO 15-SEC, to connect up to two sensor cables SEC 15
  • Universal connection module UCM 15-ESD for connection box CBO 15-ESD, to connect one sensor cable SEC 15 and up to four external sensors ESD-A5, or up to eight external sensors ESD-A5
  • Linking element between sensor cable SEC 15, external sensors ESD-A5 and connection cable CC 15
  • Approved by VdS according to EN 54-22:2020-07, approval No: G 221004, response classes A1NA2NBN, environmental group III (applied for certification A1IA2IBI)

Universal Connection Module UCM 15

Posted in SEC 15 | Comments Off on Universal Connection Module UCM 15

Connection Box CBO 15

Posted in SEC 15 | Comments Off on Connection Box CBO 15

d-LIST controller d-LCON

Posted in SEC 15 | Comments Off on d-LIST controller d-LCON

Accessories

Posted in SEC 15 | Comments Off on Accessories

Connection Box CBO 5

Posted in SEC 15 | Comments Off on Connection Box CBO 5

Connection Cable

Posted in SEC 15 | Comments Off on Connection Cable

Connection Module

Posted in SEC 15 | Comments Off on Connection Module

External Sensors

Posted in SEC 15 | Comments Off on External Sensors

Power Supply

Posted in SEC 15 | Comments Off on Power Supply

Remote Display Unit

Posted in SEC 15 | Comments Off on Remote Display Unit

SEC 15 Simulator

Posted in SEC 15 | Comments Off on SEC 15 Simulator

Sensor Cable

Posted in SEC 15 | Comments Off on Sensor Cable

Sensor Control Unit

Posted in SEC 15 | Comments Off on Sensor Control Unit

Software

Posted in SEC 15 | Comments Off on Software

Universal Connection Module UCM 15

Connection Box CBO 15

Combustion behaviour 

  • UL 94 V-2
  • UL 50 5VA / UL 746C
  • EN 60695-11-10 / IEC 60695-11-10, 960 °C
  • VDE 0471 part 11-10, 960 °C
  • CSA C 22.2

Ordering information

  • Connection Box CBO 15-SEC
    Connection of up to two sensor cables SEC 15 and up to two connection cables CC 15 to
    d-LISTcontroller cable port A / B
  • Connection Box CBO 15-ESD Art.-no.: 62-2001004-02-xx
    Connection variant 1: Connection of up to two sensor cables SEC 15 and up to two connection
    cables CC 15 to d-LISTcontroller cable port A / B
    Connection variant 2: Connection of one sensor cable SEC 15, up to four external sensors
    ESD-A5, and up to two connection cables CC 15 to d-LISTcontroller
    cable port A / B
    Connection variant 3: Connection of up to eight external sensors ESD-A5 and up to two
    connection cables CC 15 to d-LISTcontroller cable port A / B

 

 

Connection Box CBO 15

This is the new Connection box to be used with up to two sensor Sec 15 cables

 

General data

  • Case material: Glass-fibre reinforced polycarbonate, free from halogen, silicone, heavy metal and PVC, UV- and weather-proof
  • Ingress protection: IP 66 according to EN 60529:2000
  • Protection class: II – protective insulation according to VDE 0106
  • Impact resistance: IK 08, according to DIN EN 50102 (VDE 0470-100)
  • Case body: Light grey, similar to RAL 7035
  • Case lid: Red, similar to RAL 3020
  • Gasket: Polyurethane
  • Mounting: Mounting screws outside of sealed enclosure interior
  • Operating temperature: -35 °C … +70 °C, up to +80 °C short term
  • Storage Conditions: 0 °C … +60 °C, 30% … 70% relative humidity, non condensing, prevention against shock, vibration, dust, electrostatic discharge ESD, UV light
  • Cable glands: Metric, with O-Ring
  • Weight: 0,48 … 0,55 kg (depending on configuration)
  • Dimensions: 130,0 x 130,0 x 74,7 mm, without cable glands (w x h x d)

 

CBO 15 Models

CBO 15-SEC                                                                                                 CBO 15-ESD

Universal Connection Module UCM 15

Posted in SEC 15 | Comments Off on Universal Connection Module UCM 15

Connection Box CBO 15

Posted in SEC 15 | Comments Off on Connection Box CBO 15

d-LIST controller d-LCON

Posted in SEC 15 | Comments Off on d-LIST controller d-LCON

Accessories

Posted in SEC 15 | Comments Off on Accessories

Connection Box CBO 5

Posted in SEC 15 | Comments Off on Connection Box CBO 5

Connection Cable

Posted in SEC 15 | Comments Off on Connection Cable

Connection Module

Posted in SEC 15 | Comments Off on Connection Module

External Sensors

Posted in SEC 15 | Comments Off on External Sensors

Power Supply

Posted in SEC 15 | Comments Off on Power Supply

Remote Display Unit

Posted in SEC 15 | Comments Off on Remote Display Unit

SEC 15 Simulator

Posted in SEC 15 | Comments Off on SEC 15 Simulator

Sensor Cable

Posted in SEC 15 | Comments Off on Sensor Cable

Sensor Control Unit

Posted in SEC 15 | Comments Off on Sensor Control Unit

Software

Posted in SEC 15 | Comments Off on Software

Universal Connection Module UCM 15

d-LIST controller d-LCON

General Information

  • Dimensions: 289,5 x 177,5 x 91,0 mm (w x h x d, maximum inclusive cable glands)
  • Case material: Aluminium, powder coated in RAL 7035, light grey
  • Power supply: +10,5 V … +30 V DC
  • Outputs: Two optical outputs ( +5 V … +30 V DC, 500 mA)
  • Inputs: Four optical inputs and 1 x external reset (+5 V … +30 V DC, 3 mA)
  • Storage Conditions: 0 °C … +60 °C, 30% … 70% relative humidity, non condensing, prevention against shock, vibration, dust, electrostatic discharge ESD, UV light

d-LCON

  • Weight: 1,95 kg, inclusive cable glands
  • Current draw: Maximum 145 mA (normal operation) / maximum 150 mA (alarm) at 24 V DC and +25°C
  • Power consumption: Maximum 4,4 W at +10,5 V DC and +25°C
  • Relays: One each for common fire alarm and common fault per cable port A / B

d-LCON + Relay board REL 835

  • Weight: 2,1 kg, inclusive cable glands
  • Current draw: Maximum 175 mA (normal operation) / maximum 210 mA (alarm) at 24 V DC and +25°C
  • Power consumption: Maximum 5,5 W at +10,5 V DC and +25°C
  • Relays: One each for common fire alarm and common fault per cable port A / B as well as 16 zonal relays for alarms, faults or pre-alarms per programmed sensor cable zone

 

Sensor Control Unit d-LIST controller

The SCU d-List Controller works as the control and evaluation unit of the resettable line-type heat detector d-LIST

 

 

Features

  • Measurement resolution of 0,0625 °C with a repeatability of ± 0.0625K along the entire sensor cable length
  • 10 second measuring cycle
  • Expandable with relay board REL 835 with 16 relays, or adapter plates for alarm transponder or XLM 35
  • From 255 possible zones, up to 32 alarm zones can be programmed differently on 16 alarm relays
  •  Up to 16 individually programmable zones
  • Two sensor cable inputs A and B
  • May be used with sensor cable SEC 15, external sensors ESD, connection boxes CBO 15

Specifications

  • Operating temperature: -25 °C …+70 °C (environmental class III)
  • Ingress protection: IP 65
  • Measurement resolution: 0,0625 °C, output via protocol interface 0,1 °C
  • Repeatability: ± 0,0625 K, output via protocol interface ± 0,1K
  • Sensor quantity: Min. 10 / max. 100 sensors per sensor cable port A / B
  • Sensor cable length: Min. 10 m / max. 320 m per sensor cable port (max. 350 m including connection cable CC 15)

Ordering information

  • d-list Controller d-Lcon

 

Universal Connection Module UCM 15

Posted in SEC 15 | Comments Off on Universal Connection Module UCM 15

Connection Box CBO 15

Posted in SEC 15 | Comments Off on Connection Box CBO 15

d-LIST controller d-LCON

Posted in SEC 15 | Comments Off on d-LIST controller d-LCON

Accessories

Posted in SEC 15 | Comments Off on Accessories

Connection Box CBO 5

Posted in SEC 15 | Comments Off on Connection Box CBO 5

Connection Cable

Posted in SEC 15 | Comments Off on Connection Cable

Connection Module

Posted in SEC 15 | Comments Off on Connection Module

External Sensors

Posted in SEC 15 | Comments Off on External Sensors

Power Supply

Posted in SEC 15 | Comments Off on Power Supply

Remote Display Unit

Posted in SEC 15 | Comments Off on Remote Display Unit

SEC 15 Simulator

Posted in SEC 15 | Comments Off on SEC 15 Simulator

Sensor Cable

Posted in SEC 15 | Comments Off on Sensor Cable

Sensor Control Unit

Posted in SEC 15 | Comments Off on Sensor Control Unit

Software

Posted in SEC 15 | Comments Off on Software

Industrial Fires: impacts and solutions

Industrial Fires: impacts and solutions

Industrial and commercial fires in the UK are a reoccurring and constant threat to both the lives and livelihoods of hundreds of people and businesses. From 2010-2015 it was estimated that £1 billion was lost to the UK economy as a direct impact of these fires with 5,000 jobs lost as a result. Fires in the UK account for around £230 million loss to businesses every year and in many cases of fires that occur within the premises of privately owned businesses, the business never recovers. The issue of fire within the UK then is a very large one, with around 26,800 industrial and commercial fires attended by the fire department in the past three years. An emerging trend within these statistics is the number of significant fires in the waste treatment sector, this is because heat is produced very easily when waste is piled up and left alone. This is evident in the fact that there are around 300 significant fires at waste treatment facilities every year, these fires are often fast growing and very difficult to extinguish.
In waste treatment facilities, recycling plants and countless other industrial settings when a fire starts it is very unlikely that it will be extinguished before a vast amount of damage has been done to the building, goods, infrastructure etc. When this is the case the need to prevent a fire in the first place is paramount, one way to do this is to measure the air temperature of the site to register any subtle rise in temperature to then take action before a fire has the chance to ignite. This is when the LISTEC SEC 15 d-list heat detection cable really comes into its own, it can detect a 0.1°C change in air temperature and works from -40°C to 120°C. The cable can take readings of the air temperature every second along two 250m lengths of cable (per connector box) and the system can be programmed to pre alarm at a certain rate of rise in the ambient temperature to initially warn users of a potential issue and then a full alarm when the heat rises to critical levels. Unlike air aspirated systems LISTEC can’t get clogged up and blocked which also makes it extremely reliable and reduces the amount of maintenance that is needed. These features of the LISTEC cable, and many more, are why it is so effective against the prevention of fire, which could save lives and prevent a catastrophic loss of capital.
If you would like to learn more about the LISTEC system please get in touch or click here.
Information gained from BSA and the NFCC websites.
Universal Connection Module UCM 15

Accessories

Mounting Device

High quality polyamid clamps with various combinations of screw and dowel. Stainless steel bracket. Stainless steel fixing sets (J-clamo, dowel and nut) in various qualities. Applicatory cable ties for the fixing of the sensor cables onto messenger cables. Drilling and setting tools, optimized for the stainless steel dowels

Service Case

Basic set of service and repair tools, with crimping tool, connection and repair material in polycarbonat case.

End Cap

End cap for sensor cable SEC 20 and SEC 15

Crimping Tool

LIST crimping tool for 2-and 4-core (SEC 15 and SEC 20) flat cable connectors

Accessories

Posted in SEC 20 | Comments Off on Accessories

Cabinets

Posted in SEC 20 | Comments Off on Cabinets

Connection Cable

Posted in SEC 20 | Comments Off on Connection Cable

Connection Box

Posted in SEC 20 | Comments Off on Connection Box

Connection Module

Posted in SEC 20 | Comments Off on Connection Module

Data Management Unit

Posted in SEC 20 | Comments Off on Data Management Unit

Ethernet-Switch

Posted in SEC 20 | Comments Off on Ethernet-Switch

External Sensors

Posted in SEC 20 | Comments Off on External Sensors

LIST cable tester

Posted in SEC 20 | Comments Off on LIST cable tester

LIST controller

Posted in SEC 20 | Comments Off on LIST controller

Power Supply

Posted in SEC 20 | Comments Off on Power Supply

Relay Module

Posted in SEC 20 | Comments Off on Relay Module

SEC 20 Simulator

Posted in SEC 20 | Comments Off on SEC 20 Simulator

Sensor Cable

Posted in SEC 20 | Comments Off on Sensor Cable

Software

Posted in SEC 20 | Comments Off on Software

Universal Connection Module UCM 15

Accessories

Mounting Device

High quality polyamid clamps with various combinations of screw and dowel. Stainless steel bracket. Stainless steel fixing sets (J-clamo, dowel and nut) in various qualities. Applicatory cable ties for the fixing of the sensor cables onto messenger cables. Drilling and setting tools, optimized for the stainless steel dowels

Service Case

Basic set of service and repair tools, with crimping tool, connection and repair material in polycarbonat case.

End Cap

End cap for sensor cable SEC 20 and SEC 15

Crimping Tool

LIST crimping tool for 2-and 4-core (SEC 15 and SEC 20) flat cable connectors

Universal Connection Module UCM 15

Posted in SEC 15 | Comments Off on Universal Connection Module UCM 15

Connection Box CBO 15

Posted in SEC 15 | Comments Off on Connection Box CBO 15

d-LIST controller d-LCON

Posted in SEC 15 | Comments Off on d-LIST controller d-LCON

Accessories

Posted in SEC 15 | Comments Off on Accessories

Connection Box CBO 5

Posted in SEC 15 | Comments Off on Connection Box CBO 5

Connection Cable

Posted in SEC 15 | Comments Off on Connection Cable

Connection Module

Posted in SEC 15 | Comments Off on Connection Module

External Sensors

Posted in SEC 15 | Comments Off on External Sensors

Power Supply

Posted in SEC 15 | Comments Off on Power Supply

Remote Display Unit

Posted in SEC 15 | Comments Off on Remote Display Unit

SEC 15 Simulator

Posted in SEC 15 | Comments Off on SEC 15 Simulator

Sensor Cable

Posted in SEC 15 | Comments Off on Sensor Cable

Sensor Control Unit

Posted in SEC 15 | Comments Off on Sensor Control Unit

Software

Posted in SEC 15 | Comments Off on Software

Universal Connection Module UCM 15

Connection Cable

SR 114H 4 Core+E 1.5 Red (CC 20)

 

Cable construction

ConductorSolid plain annealed copper wires
InsulationFire Resistant Silicone Rubber, Type EI2 to BS EN 50363-1
Metallic ScreenAluminium backed polyester tape helically applied with 125% coverage, aluminium in continuous contact with the uninsulated earth conductor for 2,3,4 core) or drain wire (for 7,12 or 19 core)
SeparatorPolyester tape helically applied with 25% overlap
ArmourOptions available SWA (Steel Wire Armour) GSWB (Galvanised Steel Wire Braid)
SheathLSZH thermoplastic compound, flame retardant, abrasion resistant, type LTS3 to BS 7655-6.1.
Mechanical and installation characteristics
Operating temperature for the cable (after installation)-40°C ÷ +90°C
Operating temperature (only insulation)-40°C ÷ +180°C (max +200 °C)

 

Accessories

Posted in SEC 20 | Comments Off on Accessories

Cabinets

Posted in SEC 20 | Comments Off on Cabinets

Connection Cable

Posted in SEC 20 | Comments Off on Connection Cable

Connection Box

Posted in SEC 20 | Comments Off on Connection Box

Connection Module

Posted in SEC 20 | Comments Off on Connection Module

Data Management Unit

Posted in SEC 20 | Comments Off on Data Management Unit

Ethernet-Switch

Posted in SEC 20 | Comments Off on Ethernet-Switch

External Sensors

Posted in SEC 20 | Comments Off on External Sensors

LIST cable tester

Posted in SEC 20 | Comments Off on LIST cable tester

LIST controller

Posted in SEC 20 | Comments Off on LIST controller

Power Supply

Posted in SEC 20 | Comments Off on Power Supply

Relay Module

Posted in SEC 20 | Comments Off on Relay Module

SEC 20 Simulator

Posted in SEC 20 | Comments Off on SEC 20 Simulator

Sensor Cable

Posted in SEC 20 | Comments Off on Sensor Cable

Software

Posted in SEC 20 | Comments Off on Software

Universal Connection Module UCM 15

Connection Box CBO 5

Connection Box CBO 5

General Data

  • Case material: Polyester, glass-fibre reinforced, halogen-free 
  • Ingress protection: IP 66 according to EN 60529:2000
  • Protection class: II – protective insulation according to VDE 0106
  • Impact resistance: IK 08, according to DIN EN 50102 (VDE 0470-100)
  • Case body: Grey, similar to RAL 7035
  • Case lid: Red, similar to RAL 3020
  • Gasket: Polyurethane
  • Mounting: Mounting screws outside of sealed enclosure interior
  • Operating temperature: -35 °C … +60 °C, up to +80 °C short term
  • Cable glands: Metric, with O-Ring
  • Weight: 0,48 … 0,55 kg (depending on configuration)
  • Dimensions: 130,0 x 130,0 x 74,7 mm, without cable glands (w x h x d)

Combustion behaviour

  • UL 94 V-2
  • UL50 5VA / UL 746C
  • EN 60695-11-10 / IEC 60695-11-10, 960 °C
  • VDE 0471 part 11-10, 960 °C
  • CSA C 22.2
Ordering Information

  • Connection Box CBO 5-SEC. Connection of up to two sensor cables SEC 15 and up to two connection cables CC 15 to SCU 800 port A or B
  • Connection Box CBO 5-ESD-T. TYPE1: Connection of up to two sensor cables SEC 15 and up to two connection cables CC 15 to SCU 800 port A or B. TYPE2: Connection of one sensor cable SEC15, Up to four external sensors ESD, and up to two connection cables CC 15 to SCU 800 port A or B. TYPE3: Connection of up to eight external sensors ESD and up to two connection cables CC15 to SCU800 port A or B.
  • Connection box CBO 5/1. Connection of up to two sensor cables SEC 15 and up to two connection cables CC 15 to SCU 800 port A or B
  • Connection Box CBO 5/2. Connection of two sensor cables Sec 15 and one connection cable CC15 each to SCU800 port A and B
Scope of Delivery

  • CBO 5-SEC,  including universal connection module UCM-SEC, mounting materials, metric cable glands and connection materials
  • CBO 5-ESD-T, including universal connection module UCM-ESD mounting materials, metric cable glands and connection materials
  • Connection Box CBO 5/1,including one connection module CCM 150-A materials, metric cable glands and connection materials
  • Connection Box CBO 5/2,including two connection modules CCM 150-A materials, metric cable glands and connection materials

Connection Box ATEX

Connection box for sensor cable SEC 15 and external sensors ESD in potentially explosive atmospheres (Zone 2 and 22).

Universal Connection Module UCM 15

Posted in SEC 15 | Comments Off on Universal Connection Module UCM 15

Connection Box CBO 15

Posted in SEC 15 | Comments Off on Connection Box CBO 15

d-LIST controller d-LCON

Posted in SEC 15 | Comments Off on d-LIST controller d-LCON

Accessories

Posted in SEC 15 | Comments Off on Accessories

Connection Box CBO 5

Posted in SEC 15 | Comments Off on Connection Box CBO 5

Connection Cable

Posted in SEC 15 | Comments Off on Connection Cable

Connection Module

Posted in SEC 15 | Comments Off on Connection Module

External Sensors

Posted in SEC 15 | Comments Off on External Sensors

Power Supply

Posted in SEC 15 | Comments Off on Power Supply

Remote Display Unit

Posted in SEC 15 | Comments Off on Remote Display Unit

SEC 15 Simulator

Posted in SEC 15 | Comments Off on SEC 15 Simulator

Sensor Cable

Posted in SEC 15 | Comments Off on Sensor Cable

Sensor Control Unit

Posted in SEC 15 | Comments Off on Sensor Control Unit

Software

Posted in SEC 15 | Comments Off on Software

Universal Connection Module UCM 15

Connection Cable

SR 114H 2 Core+E 1.5 red (CC15)

Cable construction

ConductorSolid plain annealed copper wires
InsulationFire Resistant Silicone Rubber, Type EI2 to BS EN 50363-1
Metallic ScreenAluminium backed polyester tape helically applied with 125% coverage, aluminium in continuous contact with the uninsulated earth conductor for 2,3,4 core) or drain wire (for 7,12 or 19 core)
SeparatorPolyester tape helically applied with 25% overlap
ArmourOptions available SWA (Steel Wire Armour) GSWB (Galvanised Steel Wire Braid)
SheathLSZH thermoplastic compound, flame retardant, abrasion resistant, type LTS3 to BS 7655-6.1.
Mechanical and installation characteristics
Operating temperature for the cable (after installation)-40°C ÷ +90°C
Operating temperature (only insulation)-40°C ÷ +180°C (max +200 °C)

Universal Connection Module UCM 15

Posted in SEC 15 | Comments Off on Universal Connection Module UCM 15

Connection Box CBO 15

Posted in SEC 15 | Comments Off on Connection Box CBO 15

d-LIST controller d-LCON

Posted in SEC 15 | Comments Off on d-LIST controller d-LCON

Accessories

Posted in SEC 15 | Comments Off on Accessories

Connection Box CBO 5

Posted in SEC 15 | Comments Off on Connection Box CBO 5

Connection Cable

Posted in SEC 15 | Comments Off on Connection Cable

Connection Module

Posted in SEC 15 | Comments Off on Connection Module

External Sensors

Posted in SEC 15 | Comments Off on External Sensors

Power Supply

Posted in SEC 15 | Comments Off on Power Supply

Remote Display Unit

Posted in SEC 15 | Comments Off on Remote Display Unit

SEC 15 Simulator

Posted in SEC 15 | Comments Off on SEC 15 Simulator

Sensor Cable

Posted in SEC 15 | Comments Off on Sensor Cable

Sensor Control Unit

Posted in SEC 15 | Comments Off on Sensor Control Unit

Software

Posted in SEC 15 | Comments Off on Software

Universal Connection Module UCM 15

Connection Module

Connection Module CCM 150_A

 

  • Connection module for DIN-rail installation in connection box CBO 5/1 and CBO5/2
  • Linking element between sensor cable SEC15 and connection cable CC15

Universal Connection Module UCM

  • Universal connection module UCM-SEC for connection box CBO 5 SEC to connect up to two sensor cables SEC 15
  • Universal connection module UCM-ESD for connection box CBO 5 ESD to connect one sensor cables SEC 15 and up to four external sensors ESD or up to eight external sensors ESD ]
  • Linking element between sensor cable SEC 15 external sensors ESD and connection cable CC15

SECcon connector

  • Pre-assembled cable plugs and sockets, 3 pins
  • No need for special tooling and skills on-site
  • Drastic reduction of install and commissioning times
  • To connect sensor cable SEC 15 and connection cable CC15 or to connect two sensor cables SEC 15

Universal Connection Module UCM 15

Posted in SEC 15 | Comments Off on Universal Connection Module UCM 15

Connection Box CBO 15

Posted in SEC 15 | Comments Off on Connection Box CBO 15

d-LIST controller d-LCON

Posted in SEC 15 | Comments Off on d-LIST controller d-LCON

Accessories

Posted in SEC 15 | Comments Off on Accessories

Connection Box CBO 5

Posted in SEC 15 | Comments Off on Connection Box CBO 5

Connection Cable

Posted in SEC 15 | Comments Off on Connection Cable

Connection Module

Posted in SEC 15 | Comments Off on Connection Module

External Sensors

Posted in SEC 15 | Comments Off on External Sensors

Power Supply

Posted in SEC 15 | Comments Off on Power Supply

Remote Display Unit

Posted in SEC 15 | Comments Off on Remote Display Unit

SEC 15 Simulator

Posted in SEC 15 | Comments Off on SEC 15 Simulator

Sensor Cable

Posted in SEC 15 | Comments Off on Sensor Cable

Sensor Control Unit

Posted in SEC 15 | Comments Off on Sensor Control Unit

Software

Posted in SEC 15 | Comments Off on Software

Universal Connection Module UCM 15

External Sensors

External sensor ESD

 

Features

  • Highly resistant against corrosion, pitting and a multitude of chemicals
  • Hermetically sealed by a thermally conductive potting compound
  • Prismatic stainless steel housing with a 4 mm mounting bore for fitting to measurement object
  • Cylindrical stainless steel housing for feeler application
  • To be used with sensor control unit SCU 800
  • May be combined with d-LIST sensor cable SEC 15
  • Maximum number of external sensors each for inputs A and B  of a sensor control unit SCU 800: Up to 50 external sensors with a total cable length of up to 100 m From 51 to 99 external sensors with a total cable length of up to 50 m In combination with sensor cable SEC 15 four external sensors at each sensor cable end with a total cable length of up to 200 m

General data

  • Ingress protection: IP 64
  • Housing material: Material no.1.4571 (DIN EN X6 CrNiMoTi 17-12-2)
  • Cable isolation material: FEP (Fluorinated Ethylene Propylene)
  • Storage Conditions: 0°C …+60°C, 30% … 70% relative humidity, non condensing, prevention against shock, vibration, dust, electrostatic discharge ESD, UV light

Sensor specifications

  • Measurement range:: -40°C … +120 °C
  • Measurement resolution: 0,1 °C
  • Repeatability:  0,1 K
  • Power supply: 5 V DC via SCU 800

Ordering information

  • External sensor ESD-A5-EL-01 (1 m connection cable, prismatic)
  • External sensor ESD-A5-EL-02 (2 m connection cable, prismatic)
  • External sensor ESD-A5-EL-03 (3 m connection cable, prismatic)
  • External sensor ESD-A5-EL-04 (4 m connection cable, prismatic)
  • External sensor ESD-A5-EL-05 (5 m connection cable, prismatic)
  • External sensor ESD-A5-EL-010 (10 m connection cable, prismatic)
  • External sensor ESD-A5-RL-01 (1 m connection cable, cylindrical)
  • External sensor ESD-A5-RL-02 (2 m connection cable, cylindrical)
  • External sensor ESD-A5-RL-03 (3 m connection cable, cylindrical)
  • External sensor ESD-A5-RL-04 (4 m connection cable, cylindrical)
  • External sensor ESD-A5-RL-05 (5 m connection cable, cylindrical)
  • External sensor ESD-A5-RL-010 (10 m connection cable, cylindrical)

Scope of delivery

  • External sensor with integral connection cable (length according to order)
  • Production of file

External sensor ESD-Ex

 

Features

  • ATEX marking for use in zones 2 and 22
  • Highly resistant against corrosion, pitting and a multitude of chemicals
  • Hermetically sealed by a thermally conductive potting compound
  • Prismatic stainless steel housing with a 4 mm mounting bore for fitting to measurement object
  • Cylindrical stainless steel housing for feeler application
  • To be used with sensor control unit SCU 800
  • May be combined with d-LIST sensor cable SEC 15
  • Maximum number of external sensors each for inputs A and B  of a sensor control unit SCU 800: Up to 50 external sensors with a total cable length of up to 100 m From 51 to 99 external sensors with a total cable length of up to 50 m In combination with sensor cable SEC 15 four external sensors at each sensor cable end with a total cable length of up to 200 m

General data

  • Type of protection zone 2: Ex II 3G Ex nA IIC T4 Gc
  • Type of protection zone 22: Ex II 3D Ex tc IIIB T125 °C Dc
  • Operating temperature: -20 °C…+70 °C
  • Ingress protection: IP 64
  • Cable routing: EN 60079-0 / 26.4.2 routing protected against mechanical impact energy
  • Connection box: CBO 5-Ex within Ex zone, CBO 5-ESD outside
  • Housing material: Material no.1.4571 (DIN EN X6 CrNiMoTi 17-12-2)
  • Cable isolation material: FEP (Fluorinated Ethylene Propylene)
  • Storage Conditions: 0°C …+60°C, 30% … 70% relative humidity, non condensing, prevention against shock, vibration, dust, electrostatic discharge ESD, UV light

Sensor specifications

  • Measurement range:: -40°C … +120 °C
  • Measurement resolution: 0,1 °C
  • Repeatability:  0,1 K
  • Power supply: 5 V DC via SCU 800

Ordering information

  • External sensor ESD-A5-EL-02 (2 m connection cable, prismatic)
  • External sensor ESD-A5-EL-05 (5 m connection cable, prismatic)
  • External sensor ESD-A5-EL-010 (10 m connection cable, prismatic)
  • External sensor ESD-A5-RL-02 (2 m connection cable, cylindrical)
  • External sensor ESD-A5-RL-05 (5 m connection cable, cylindrical)
  • External sensor ESD-A5-RL-010 (10 m connection cable, cylindrical)
  • ATEX Marking for external sensor ESD

Scope of delivery

  • External sensor with integral connection cable (length according to order)
  • ATEX marking
  • Production of file

Universal Connection Module UCM 15

Posted in SEC 15 | Comments Off on Universal Connection Module UCM 15

Connection Box CBO 15

Posted in SEC 15 | Comments Off on Connection Box CBO 15

d-LIST controller d-LCON

Posted in SEC 15 | Comments Off on d-LIST controller d-LCON

Accessories

Posted in SEC 15 | Comments Off on Accessories

Connection Box CBO 5

Posted in SEC 15 | Comments Off on Connection Box CBO 5

Connection Cable

Posted in SEC 15 | Comments Off on Connection Cable

Connection Module

Posted in SEC 15 | Comments Off on Connection Module

External Sensors

Posted in SEC 15 | Comments Off on External Sensors

Power Supply

Posted in SEC 15 | Comments Off on Power Supply

Remote Display Unit

Posted in SEC 15 | Comments Off on Remote Display Unit

SEC 15 Simulator

Posted in SEC 15 | Comments Off on SEC 15 Simulator

Sensor Cable

Posted in SEC 15 | Comments Off on Sensor Cable

Sensor Control Unit

Posted in SEC 15 | Comments Off on Sensor Control Unit

Software

Posted in SEC 15 | Comments Off on Software

Universal Connection Module UCM 15

Data Management Unit

DMU 6000-S

 

  • Data Management Unit DMU 6000-S (with visualisation software LISTgraph II, interface converter)
  • Robust aluminium case
  • Fan-less design
  • Various I/O interfaces available
  • Watchdog
  • Operating system Windows 7 Pro 32-Bit
  • CE / FCC Class A certified
  • Cabinet installation with 19” shelf / 2 U
  • Temperature range from -5 °C … -55 °C

DMU 6012-S

 

Visualisation Module for the display and storage of messages, temperature data and graphics, 12″ touch screen; various interfaces, 7U 19″-sub-rack; supply input: 24 Vdc; operating system: Windows 7 Ultimate

 

Accessories

Posted in SEC 20 | Comments Off on Accessories

Cabinets

Posted in SEC 20 | Comments Off on Cabinets

Connection Cable

Posted in SEC 20 | Comments Off on Connection Cable

Connection Box

Posted in SEC 20 | Comments Off on Connection Box

Connection Module

Posted in SEC 20 | Comments Off on Connection Module

Data Management Unit

Posted in SEC 20 | Comments Off on Data Management Unit

Ethernet-Switch

Posted in SEC 20 | Comments Off on Ethernet-Switch

External Sensors

Posted in SEC 20 | Comments Off on External Sensors

LIST cable tester

Posted in SEC 20 | Comments Off on LIST cable tester

LIST controller

Posted in SEC 20 | Comments Off on LIST controller

Power Supply

Posted in SEC 20 | Comments Off on Power Supply

Relay Module

Posted in SEC 20 | Comments Off on Relay Module

SEC 20 Simulator

Posted in SEC 20 | Comments Off on SEC 20 Simulator

Sensor Cable

Posted in SEC 20 | Comments Off on Sensor Cable

Software

Posted in SEC 20 | Comments Off on Software

Universal Connection Module UCM 15

Power Supply

Power Supply PS 240x

Features

  • Optional stand-by batteries extend operation as an uninterrupted 24 V DC supply in accordance with EN 54-4:2006
  • Short-circuit proof and current limited integral switch-mode power supply
  • Constant monitoring of stand-by battery charge and internal resistance in accordance with EN 54-4:2006
  • Maximised stand-by battery life time due to deep discharge protection and temperature compensated charging
  • Quick and easy test function to perform self-test and determine stand-by battery internal resistance
  • Earth fault monitoring configurable
  • Front-panel status display via seven LED’s
  • Acoustic fault signal
  • Powder coated sheet steel housing or 19“ front-panel
  • VdS approved

Specifications PS240

  • Mains voltage: 230 V AC +10/-20%
  • Mains frequency: 47 … 63 Hz
  • Output voltage: Typ. 27,6 V DC at 20 °C
  • Output current: Max. 2,3 A
  • Operating temperature: -5 °C … +50 °C
  • Relative humidity: Max. 95% at 40 °C (No condensation)
  • Dimensions: 230,0 x 150,0 x 54,0 mm (w x h x d, power supply module only) 478,0 x 266,0 x 63,0 mm (w x h x d, mounted on 19“ front-panel, w = 19“, h = 6U)
  • Weight: 0,5 kg power supply module only / 2,0 kg mounted on 19“ front-panel
  • Front-panel colour: RAL 9002, grey-white
  • Battery charging capacity: Up to 60 Ah, chargeable to 80% within 24 hours without load

Specifications PS2402-W

  • Mains voltage: 230 V AC +10/-20%
  • Mains frequency: 47 … 63 Hz
  • Output voltage: Typ. 27,6 V DC at 20 °C
  • Output current: Max. 2,3 A
  • Operating temperature: -5 °C … +50 °C
  • Relative humidity: Max. 95% at 40 °C (No condensation)
  • Ingress protection: IP 30
  • Dimensions: 442,0 x 462,0 x 206,0 mm (w x h x d)
  • Weight: 6,7 kg (Including power supply module, but without additional components)
  • Housing colour: RAL 9002, grey-white
  • Battery installation: Max. two 12 V / 45 Ah within housing
  • Battery charging capacity: Up to 60 Ah, chargeable to 80% within 24 hours without load

Specifications PS2408

  • Mains voltage: 230 V AC +10/-20%
  • Mains frequency: 47 … 63 Hz
  • Output voltage: Typ. 27,6 V DC at 20 °C
  • Output current: Max. 8.4 A
  • Operating temperature: -5 °C … +50 °C
  • Relative humidity: Max. 95% at 40 °C (No condensation)
  • Dimensions: 292,0 x 220,0 x 72,0 mm (w x h x d, power supply module only) 478,0 x 266,0 x 83,0 mm (w x h x d, mounted on 19“ front-panel, w = 19“, h = 6U)
  • Weight: 2,2 kg power supply module only / 3,8 kg mounted on 19“ front-panel
  • Front-panel colour: RAL 9002, grey-white
  • Battery charging capacity: Up to 220 Ah, chargeable to 80% within 24 hours without load

Specifications PS2408-W

  • Mains voltage: 230 V AC +10/-20%
  • Mains frequency: 47 … 63 Hz
  • Output voltage: Typ. 27,6 V DC at 20 °C
  • Output current: Max. 8,4 A
  • Operating temperature: -5 °C … +50 °C
  • Relative humidity: Max. 95% at 40 °C (No condensation)
  • Ingress protection: IP 30
  • Dimensions: 442,0 x 462,0 x 206,0 mm (w x h x d)
  • Weight: 8,4 kg (Including power supply module, but without additional components)
  • Housing colour: RAL 9002, grey-white
  • Battery installation: Max. two 12 V / 45 Ah within housing
  • Battery charging capacity: Up to 220 Ah, chargeable to 80% within 24 hours without load

Ordering information

  • PS 4202 (Power supply mounted on 19“ front-panel)
  • PS 2402-W (Power supply mounted in housing)
  • PS 2408 (Power supply mounted on 19“ front-panel)
  • PS 2408 -W (Power supply mounted in housing)

Scope of delivery

  • PS 4202 with mounting accessories and documentation
  • PS 2402-W with mounting accessories and documentation
  • PS 2408 with mounting accessories and documentation
  • PS 2408-W with mounting accessories and documentation

Universal Connection Module UCM 15

Posted in SEC 15 | Comments Off on Universal Connection Module UCM 15

Connection Box CBO 15

Posted in SEC 15 | Comments Off on Connection Box CBO 15

d-LIST controller d-LCON

Posted in SEC 15 | Comments Off on d-LIST controller d-LCON

Accessories

Posted in SEC 15 | Comments Off on Accessories

Connection Box CBO 5

Posted in SEC 15 | Comments Off on Connection Box CBO 5

Connection Cable

Posted in SEC 15 | Comments Off on Connection Cable

Connection Module

Posted in SEC 15 | Comments Off on Connection Module

External Sensors

Posted in SEC 15 | Comments Off on External Sensors

Power Supply

Posted in SEC 15 | Comments Off on Power Supply

Remote Display Unit

Posted in SEC 15 | Comments Off on Remote Display Unit

SEC 15 Simulator

Posted in SEC 15 | Comments Off on SEC 15 Simulator

Sensor Cable

Posted in SEC 15 | Comments Off on Sensor Cable

Sensor Control Unit

Posted in SEC 15 | Comments Off on Sensor Control Unit

Software

Posted in SEC 15 | Comments Off on Software

Universal Connection Module UCM 15

Remote Display Unit

Remote Display Unit RDU 316

Features

  • Remote display unit for controller messages from a distance of up to 1.000 m via RS485 connection
  • May be combined with up to 31 control units SCU 800
  • May be combined with one control unit LISTcontroller SEC or LISTcontroller LB
  • Alarm indication on unit front via LED
  • Highly durable via utilisation of maintenance-free components, RoHS compliant
  • Very low energy consumption

General data

  • Operating temperature: 0 °C … +60 °C
  • Dimensions: 144,2 x 114,2 x 60,0 mm, (w x h x d, maximum including cable-glands)
  • Case material: Thermoplast ASA/PC, halogen-free
  • Weight: 0,35 kg
  • Power supply: 10 V … 30 V DC
  • Current draw: 42 mA (normal) / 105 mA (alarm), at 24 V DC
  • Power consumption: Max. 2,5 W
  • Ingress protection: IP 65
  • Finish: RAL 7035, light grey
  • Cover screws: Stainless steel, material 1.4567 (DIN EN X3 CrNiCu 18-9-4), captive
  • Gasket: Silicone
  • Integrated lid support: Polypropylen (PP)
  • Mounting: Mounting screws outside enclosure interior
  • Cable gland: Membrane cable-gland CLIXX 20

Combustion behaviour

  • UL 94 V-0, self-extinguishing
  • EN 60695-11-10 / IEC 60695-11-10
  • VDE 0471 part 11-10
  • CSA C 22.2

Front panel displays

  • Operation: LED green
  • Data transmission: LED blue
  • Fault: LED orange
  • Fire alarm: LED red
  • LC-Display: Plain text messages and menu navigation (blue information display only for LISTController LB)

Front Panel operation

  • 5 button membrane keyboard for menu navigation, data and function input

Connection and interfaces

  • 24 V DC: Power supply
  • RS485: RS485 data-interface for LIST communication to SCU 800 or LISTcontroller
  • USB: For software updates

Ordering information

  • Remote Display Unit RDU 316

Scope of delivery

  • Remote Display Unit RDU 316, including LISTmemory USB flash drive

Universal Connection Module UCM 15

Posted in SEC 15 | Comments Off on Universal Connection Module UCM 15

Connection Box CBO 15

Posted in SEC 15 | Comments Off on Connection Box CBO 15

d-LIST controller d-LCON

Posted in SEC 15 | Comments Off on d-LIST controller d-LCON

Accessories

Posted in SEC 15 | Comments Off on Accessories

Connection Box CBO 5

Posted in SEC 15 | Comments Off on Connection Box CBO 5

Connection Cable

Posted in SEC 15 | Comments Off on Connection Cable

Connection Module

Posted in SEC 15 | Comments Off on Connection Module

External Sensors

Posted in SEC 15 | Comments Off on External Sensors

Power Supply

Posted in SEC 15 | Comments Off on Power Supply

Remote Display Unit

Posted in SEC 15 | Comments Off on Remote Display Unit

SEC 15 Simulator

Posted in SEC 15 | Comments Off on SEC 15 Simulator

Sensor Cable

Posted in SEC 15 | Comments Off on Sensor Cable

Sensor Control Unit

Posted in SEC 15 | Comments Off on Sensor Control Unit

Software

Posted in SEC 15 | Comments Off on Software

Universal Connection Module UCM 15

SEC 15 Simulator

SEC 15 Simulator CSM 30

 

Features

  • Designed to simulate d-list sensor cable SEC 15 in test set-ups
  • Simulate sensor cable with up to 31 sensors
  • Fault simulation via toggling one of two activatable sensors
  • Alarm simulation via manual heating at the 30 sensor markings
  • To be used with sensor control unit SCU 800
  • May be combined with sensor cable SEC 15
  • Plastic case with silicone bumper

General data

  • Case material: ABS plastic, UL 94V-0
  • Dimensions: 172,2 x 85 x 34,5 mm (w x h x d)
  • Weight: 265 g

Sensor specification

  • Measurement range: -40 °C … +120 °C
  • Measurement resolution: 0,1 °C
  • Repeatability:  0,1 K
  • Supply voltage: 5 V DC via sensor control unit SCU 800

Ordering information

  • SEC 15 Simulator CSM 30

Scope of delivery

  • SEC 15 Simulator CSM 30 delivered with a 1 m connection cable

 

Universal Connection Module UCM 15

Posted in SEC 15 | Comments Off on Universal Connection Module UCM 15

Connection Box CBO 15

Posted in SEC 15 | Comments Off on Connection Box CBO 15

d-LIST controller d-LCON

Posted in SEC 15 | Comments Off on d-LIST controller d-LCON

Accessories

Posted in SEC 15 | Comments Off on Accessories

Connection Box CBO 5

Posted in SEC 15 | Comments Off on Connection Box CBO 5

Connection Cable

Posted in SEC 15 | Comments Off on Connection Cable

Connection Module

Posted in SEC 15 | Comments Off on Connection Module

External Sensors

Posted in SEC 15 | Comments Off on External Sensors

Power Supply

Posted in SEC 15 | Comments Off on Power Supply

Remote Display Unit

Posted in SEC 15 | Comments Off on Remote Display Unit

SEC 15 Simulator

Posted in SEC 15 | Comments Off on SEC 15 Simulator

Sensor Cable

Posted in SEC 15 | Comments Off on Sensor Cable

Sensor Control Unit

Posted in SEC 15 | Comments Off on Sensor Control Unit

Software

Posted in SEC 15 | Comments Off on Software

Universal Connection Module UCM 15

Sensor Cable

SEC 15-EX

 

Features

  • ATEX marking for use in zones 2 and 22
  • Complete encapsulation to protect sensors from environmental influences
  • Sensor spacing selectable to comply to project demand
  • Pinpoint sensor location via individual addresses
  • Maintenance free cable
  • Aramid fibres serve as strain relief and as reinforcement in case of fire
  • Easy mounting by use of diverse fasteners
  • Branching of cable routes via connection boxes
  • To be used with sensor control unit SCU 800
  • May be combined with d-LIST external sensors ESD
  • Up to 2 x 250 m combined cable length, respectively up to 2 x 99 sensors per sensor control unit SCU 800

General data

  • Type of protection zone 2: Ex II 3G Ex nA IIC T4 Gc
  • Operating temp. zone 2: -20 °C … +80 °C, from 70 °C protected from mechanical impact energy (EN 60079-0 / 26.4.2)
  • Type of protection zone 22: Ex II 3D Ex tc IIIC T125 °C Dc
  • Operating temp. zone 22: -20 °C … +70 °C
  • Cable diameter: Typ. 15 mm
  • Flat conductor resistance: Typ. 71 Ω / km (single conductor)
  • Sheath material: HM4 mixture, halogen-free and flame retardant, according to EN 50267-2-1:1999-04,EN50267-2-2:1999-04, EN 60332-1-2:2005-06, EN 60332-2-2:2005-06, EN 61034-2:2006-03, IEC 60754-1, IEC 60754-2
  • Weight: Typ. 0,35 kg / m
  • Sheath colour: Grey or black
  • Marking: Consecutive number printed at each sensor location, followed by cable identifier
  • Deliverable cable length: Up to 2.400 m, prefabricated cable sections on request
  • Mounting temperature: ≥ +10 °C
  • Bending radius: ≥ 25 cm
  • Verified and approved to: EN 54-5, class A1 VdS no.: G 205143

Sensor specifications

  • Measurement range: -40 °C … +120 °C
  • Measurement resolution: 0,1 °C
  • Repeatability: 0,1 K
  • Supply voltage: 5 V DC via sensor control unit SCU 800

Ordering information

  • Sensor Cable SEC 15/01 (1 m sensor spacing)
  • Sensor Cable SEC 15/02 (2 m sensor spacing)
  • Sensor Cable SEC 15/03 (3 m sensor spacing)
  • Sensor Cable SEC 15/04 (4 m sensor spacing)
  • Sensor Cable SEC 15/05 (5 m sensor spacing)
  • Sensor Cable SEC 15/xx (Customer specified sensor spacing, limited to not less than 0,25 m)
  • ATEX marking for sensor cable SEC 15 (to be ordered for every separate sensor cable section)

Scope of delivery

  • Ordered sensor cable length may be shipped as a cable ring in a carton, on a one way drum, or on loaner KTG-drum and pallet
  • ATEX markings for every separate sensor cable section

Cable construction

  • Two-core flexible flat cable with temperature sensors
  • Filler material with strain relief
  • Aluminium foil shield
  • Sheath with imprints at each sensor location

Cable Imprint sec 20 imprint

  • Imprint 1: The sensor marking is used in cable lists, delivery notes etc.
  • Imprint 2: Static marking only

SEC 15 (cat. D+F)

 

Features

  • Approved by DNV-GL, certificate-no.: 60 380 – 09 HH
  • Complete encapsulation to protect sensors from environmental influences
  • Sensor spacing selectable to comply to project demand
  • Pinpoint sensor location via individual addresses
  • Maintenance free cable
  • Aramid fibres serve as strain relief and as reinforcement in case of fire
  • Easy mounting by use of diverse fasteners
  • Branching of cable routes via connection boxes
  • To be used with sensor control unit SCU 800
  • Quick cable repair in case of mechanical damage
  • Up to 2 x 250 m combined cable length, respectively up to 2 x 99 sensors per sensor control unit SCU 800

General data

  • Operating temperature: -40 °C … +85 °C, up to +120 °C short term
  • Cable diameter: Typ. 15 mm
  • Flat conductor resistance: Typ. 71 Ω / km (single conductor)
  • Sheath material: HM4 mixture, halogen-free and flame retardant, according to EN 50267-2-1:1999-04,EN50267-2-2:1999-04, EN 60332-1-2:2005-06, EN 60332-2-2:2005-06, EN 61034-2:2006-03, IEC 60754-1, IEC 60754-2
  • Weight: Typ. 0,35 kg / m
  • Sheath colour: Grey
  • Marking: Consecutive number printed at each sensor location, followed by cable identifier
  • Deliverable cable length: Up to 2.400 m, prefabricated cable sections on request
  • Mounting temperature: ≥ +10 °C
  • Bending radius: ≥ 25 cm
  • Verified and approved to: EN 54-5, class A1 VdS no.: G 205143

Sensor specifications

  • Measurement range: -40 °C … +120 °C
  • Measurement resolution: 0,1 °C
  • Repeatability: 0,1 K
  • Supply voltage: 5 V DC via sensor control unit SCU 800

Ordering information

  • Sensor Cable SEC 15/01 (1 m sensor spacing)
  • Sensor Cable SEC 15/02 (2 m sensor spacing)
  • Sensor Cable SEC 15/03 (3 m sensor spacing)
  • Sensor Cable SEC 15/04 (4 m sensor spacing)
  • Sensor Cable SEC 15/05 (5 m sensor spacing)
  • Sensor Cable SEC 15/xx (Customer specified sensor spacing, limited to not less than 0,25 m)

Scope of delivery

  • Ordered sensor cable length may be shipped as a cable ring in a carton, on a one way drum, or on loaner KTG-drum and pallet

Cable construction

  • Two-core flexible flat cable with temperature sensors
  • Filler material with strain relief
  • Aluminium foil shield
  • Sheath with imprints at each sensor location

Cable Imprint sec 20 imprint

  • Imprint 1: The sensor marking is used in cable lists, delivery notes etc.
  • Imprint 2: Static marking only

 

 

Universal Connection Module UCM 15

Posted in SEC 15 | Comments Off on Universal Connection Module UCM 15

Connection Box CBO 15

Posted in SEC 15 | Comments Off on Connection Box CBO 15

d-LIST controller d-LCON

Posted in SEC 15 | Comments Off on d-LIST controller d-LCON

Accessories

Posted in SEC 15 | Comments Off on Accessories

Connection Box CBO 5

Posted in SEC 15 | Comments Off on Connection Box CBO 5

Connection Cable

Posted in SEC 15 | Comments Off on Connection Cable

Connection Module

Posted in SEC 15 | Comments Off on Connection Module

External Sensors

Posted in SEC 15 | Comments Off on External Sensors

Power Supply

Posted in SEC 15 | Comments Off on Power Supply

Remote Display Unit

Posted in SEC 15 | Comments Off on Remote Display Unit

SEC 15 Simulator

Posted in SEC 15 | Comments Off on SEC 15 Simulator

Sensor Cable

Posted in SEC 15 | Comments Off on Sensor Cable

Sensor Control Unit

Posted in SEC 15 | Comments Off on Sensor Control Unit

Software

Posted in SEC 15 | Comments Off on Software

Universal Connection Module UCM 15

Ethernet-Switch

Ethernet-Switch FOC LAN

  •  Ethernet/Fast Ethernet-Switch according to IEEE 802.3
  •  Industrial switch for DIN-rail installation
  • Fan-less design
  • Power supply 24 V DC
  •  6 x standard 10/100 Base TX, RJ45 ports
  • 1 x RJ11 port
  • 1 x 6-pin plug-in terminal block
  •  2 x uplink port 100Base-FX, MM-SC (multimode unit)
  •  2 x uplink port 100Base-FX, SM-SC (singlemode unit)
  • Web-interface
  • Redundancy function HIPER-ring (client / server)
  • Diagnostics via LEDs, log-file, signal contact

Accessories

Posted in SEC 20 | Comments Off on Accessories

Cabinets

Posted in SEC 20 | Comments Off on Cabinets

Connection Cable

Posted in SEC 20 | Comments Off on Connection Cable

Connection Box

Posted in SEC 20 | Comments Off on Connection Box

Connection Module

Posted in SEC 20 | Comments Off on Connection Module

Data Management Unit

Posted in SEC 20 | Comments Off on Data Management Unit

Ethernet-Switch

Posted in SEC 20 | Comments Off on Ethernet-Switch

External Sensors

Posted in SEC 20 | Comments Off on External Sensors

LIST cable tester

Posted in SEC 20 | Comments Off on LIST cable tester

LIST controller

Posted in SEC 20 | Comments Off on LIST controller

Power Supply

Posted in SEC 20 | Comments Off on Power Supply

Relay Module

Posted in SEC 20 | Comments Off on Relay Module

SEC 20 Simulator

Posted in SEC 20 | Comments Off on SEC 20 Simulator

Sensor Cable

Posted in SEC 20 | Comments Off on Sensor Cable

Software

Posted in SEC 20 | Comments Off on Software

Universal Connection Module UCM 15

External Sensors

External sensor ESA

Features

  • Highly resistant against corrosion, pitting and a multitude of chemicals
  • Hermetically sealed by a thermally conductive potting compound
  • Prismatic stainless steel housing with a 4 mm mounting bore for fitting to measurement object
  • Cylindrical stainless steel housing for feeler application
  • To be used with LIST controller
  • May be combined with LIST sensor cable SEC 20
  • Up to 3.200 m sensor cable length including external sensors ESA connection cable with 320 sensors per LISTcontroller

General data

  • Ingress protection: IP 64
  • Housing material: Material no.1.4571 (DIN EN X6 CrNiMoTi 17-12-2)
  • Cable isolation material: FEP (Fluorinated Ethylene Propylene)
  • Connection box: CBO 20-ESA

Sensor specifications

  • Measurement range:: -40°C … +150 °C
  • Measurement resolution: 0,1 °C
  • Repeatability:  0,1 K
  • Power supply: 5 V DC via List controller

Ordering information

  • External sensor ESA-A5-EL-01 (1 m connection cable, prismatic)
  • External sensor ESA-A5-EL-02 (2 m connection cable, prismatic)
  • External sensor ESA-A5-EL-03 (3 m connection cable, prismatic)
  • External sensor ESA-A5-EL-05 (5 m connection cable, prismatic)
  • External sensor ESA-A5-EL-010 (10 m connection cable, prismatic)
  • External sensor ESA-A5-RL-01 (1 m connection cable, prismatic)
  • External sensor ESA-A5-RL-02 (2 m connection cable, cylindrical)
  • External sensor ESA-A5-RL-03 (3 m connection cable, cylindrical)
  • External sensor ESA-A5-RL-05 (5 m connection cable, cylindrical)
  • External sensor ESA-A5-RL-010 (10 m connection cable, cylindrical)

Scope of delivery

  • External sensor with integral connection cable (length according to order)

External sensor ESA-Ex

Features

  • ATEX marking for use in zones 2 and 22
  • Highly resistant against corrosion, pitting and a multitude of chemicals
  • Hermetically sealed by a thermally conductive potting compound
  • Prismatic stainless steel housing with a 4 mm mounting bore for fitting to measurement object
  • Cylindrical stainless steel housing for feeler application
  • To be used with LIST controller
  • May be combined with LIST sensor cable SEC 20
  • Up to 3.200 m sensor cable length including external sensors ESA connection cable with 320 sensors per LISTcontroller

General data

  • Type of protection zone 2: Ex II 3G Ex nA IIC T4 Gc
  • Type of protection zone 22: Ex II 3D Ex tc IIIB T125 °C Dc
  • Operating temperature: -20 °C…+70 °C
  • Ingress protection: IP 64
  • Cable routing: EN 60079-0 / 26.4.2 routing protected against mechanical impact energy
  • Connection box: CBO 20-SEC/1-Ex, CBO 20-SEC/2-Ex, CBO 20-ESA/1-Ex, CBO 20-ESA/2-Ex,CBO 20-SEC-ESA-Ex within Ex zone, CBO 20-ESA outside
  • Housing material: Material no.1.4571 (DIN EN X6 CrNiMoTi 17-12-2)
  • Cable isolation material: FEP (Fluorinated Ethylene Propylene)

Sensor specifications

  • Measurement range:: -40°C … +150 °C
  • Measurement resolution: 0,1 °C
  • Repeatability:  0,1 K
  • Power supply: 5 V DC via List controller

Ordering information

  • External sensor ESA-A5-EL-02 (2 m connection cable, prismatic)
  • External sensor ESA-A5-EL-05 (5 m connection cable, prismatic)
  • External sensor ESA-A5-EL-010 (10 m connection cable, prismatic)
  • External sensor ESA-A5-RL-02 (2 m connection cable, cylindrical)
  • External sensor ESA-A5-RL-05 (5 m connection cable, cylindrical)
  • External sensor ESA-A5-RL-010 (10 m connection cable, cylindrical)

Scope of delivery

  • External sensor with integral connection cable (length according to order)
  • ATEX marking

Accessories

Posted in SEC 20 | Comments Off on Accessories

Cabinets

Posted in SEC 20 | Comments Off on Cabinets

Connection Cable

Posted in SEC 20 | Comments Off on Connection Cable

Connection Box

Posted in SEC 20 | Comments Off on Connection Box

Connection Module

Posted in SEC 20 | Comments Off on Connection Module

Data Management Unit

Posted in SEC 20 | Comments Off on Data Management Unit

Ethernet-Switch

Posted in SEC 20 | Comments Off on Ethernet-Switch

External Sensors

Posted in SEC 20 | Comments Off on External Sensors

LIST cable tester

Posted in SEC 20 | Comments Off on LIST cable tester

LIST controller

Posted in SEC 20 | Comments Off on LIST controller

Power Supply

Posted in SEC 20 | Comments Off on Power Supply

Relay Module

Posted in SEC 20 | Comments Off on Relay Module

SEC 20 Simulator

Posted in SEC 20 | Comments Off on SEC 20 Simulator

Sensor Cable

Posted in SEC 20 | Comments Off on Sensor Cable

Software

Posted in SEC 20 | Comments Off on Software

Universal Connection Module UCM 15

Sensor Control Unit

SCU 800

 

Features

  • Evaluation of temperatures measured by sensor cables SEC 15 and/or external sensors ESD
  • Two sensor cable inputs A and B
  • Alarm triggering via differential and maximum temperature evaluation
  • Response characteristic according to EN54-5, class A1, approved by VdS Schadenverhütung, VdS no.: G 205143
  • Intelligent evaluation algorithms prevent false alarms
  • Highly durable via utilisation of maintenance-free components, RoHS compliant
  • Alarm indication on unit front via LEDs
  • Low power consumption
  • Up to 64 programmable individual zones with alarm and fault status signalling to superordinate systems via protocol
  • SCU 800-03: One common fault relay and one fire alarm relay each per sensor cable input
  • SCU 800/16: 16 zone relays for fire alarms, faults and pre-alarms per programmed sensor cable zone, and one common fault relay
  • Relay outputs configurable with loop resistors for closed-circuit monitoring
  • EMC approved cover gasket
  • Metric polyamide cable-glands with NBR O-Ring and seal

Front panel displays

  • Fire alarm: LED red (1x per Sensor cable input A and B)
  • Fault: LED orange
  • Operation: LED green
  • Measuring cycle: LED orange
  • Data Transmission: LED orange

System specifications

  • Operating temperature: -25 °C …+70 °C (0 °C … +40 °C approved by VdS)
  • Ingress protection: IP 65
  • Measurement resolution: 0,1 °C
  • Repeatability:  0,1 K
  • Sensor quantity: Up to 99 sensors per sensor cable input
  • Sensor cable length: Up to 250 m per sensor cable input including connection cable CC15

Connections and interfaces

  • K1 und K2: Sensor cable inputs
  • 24 V DC: Power supply
  • RS232: For unit parameterisation or connection to superordinate systems
  • RS485: Data interface for LIST Master/Slave network, or connection to superordinate systems, or unit parameterisation
  • Relay outputs: For fire alarms and common fault signalling
  • Reset: Galvanically isolated external reset input

Supported software protocols

  • MODBUS (RTU) via serial interface RS232 or RS485

General data

  • Dimensions: 326,0 x 179,0 x 91,0 mm (w x h x d, maximum including cable-glands)
  • Case material: Aluminium, powder coated in RAL 7040, grey
  • Power supply: 21 V … 29 V DC
  • Relay outputs: Switching voltage: 48 V DC / 32 V AC max. Switching current: 250 mA max. (resistive load)
  • Input: 1 x external reset (5 V DC)

SCU 800-03:

  • Weight: 1,95 kg, including cable-glands
  • Current draw: 80 mA (normal operation) / 100 mA (alarm) at 24 V DC
  • Power consumption: Max. 2,4 W
  • Relays: 1 x fire alarm per sensor cable input, 1 x common fault

SCU 800/16:

  • Weight: 2,17 kg, including cable-glands
  • Current draw: 115 mA (normal operation) / 240 mA (alarm) at 24 V DC
  • Power consumption: Max. 5,8 W
  • Relays: 16 zone relays for fire alarms, faults and pre-alarms per programmed sensor cable zone, and one common fault relay

Ordering information

  • Sensor Control Unit SCU 800-03
  • Sensor Control Unit SCU 800/16

Scope of delivery

  • Sensor Control Unit SCU 800-03 including metric cable glands and connection materials, LISTmemory USB flash drive
  • Sensor Control Unit SCU 800/16 including metric cable glands and connection materials, LISTmemory USB flash drive

SCU 800-03-EX

 

Features

  • ATEX marking for use in zones 2 and 22
  • Evaluation of temperatures measured by sensor cables SEC 15 and/or external sensors ESD
  • Two sensor cable inputs A and B
  • Alarm triggering via differential and maximum temperature evaluation
  • Response characteristic according to EN54-5, class A1, approved by VdS Schadenverhütung, VdS no.: G 205143
  • Intelligent evaluation algorithms prevent false alarms
  • Highly durable via utilisation of maintenance-free components, RoHS compliant
  • Alarm indication on unit front via LEDs
  • Low power consumption
  • Up to 64 programmable individual zones with alarm and fault status signalling to superordinate systems via protocol
  • One common fault relay and one fire alarm relay each per sensor cable input
  • Relay outputs configurable with loop resistors for closed-circuit monitoring
  • Mounting via wall-mount adaptors that may be oriented horizontally or vertically
  • EMC approved cover gasket
  • Metric polyamide Ex cable-glands with NBR O-Ring and TPE seal

Front panel displays

  • Fire alarm: LED red (1x per Sensor cable input A and B)
  • Fault: LED orange
  • Operation: LED green
  • Measuring cycle: LED orange
  • Data Transmission: LED orange

System specifications

  • Type of protection zone 2: Ex II 3G Ex nA IIC T4 Gc
  • Type of protection zone 22: Ex II 3D Ex tc IIIB T125 °C Dc
  • Operating temperature: -25 °C …+70 °C (0 °C … +40 °C approved by VdS)
  • Ingress protection: IP 65
  • Measurement resolution: 0,1 °C
  • Repeatability:  0,1 K
  • Sensor quantity: Up to 99 sensors per sensor cable input
  • Sensor cable length: Up to 250 m per sensor cable input including connection cable CC15

Connections and interfaces

  • K1 und K2: Sensor cable inputs
  • 24 V DC: Power supply
  • RS232: For unit parameterisation or connection to superordinate systems
  • RS485: Data interface for LIST Master/Slave network, or connection to superordinate systems, or unit parameterisation
  • Relay outputs: For fire alarms and common fault signalling
  • Reset: Galvanically isolated external reset input

Supported software protocols

  • MODBUS (RTU) via serial interface RS232 or RS485

General data

  • Dimensions: 462 x 452 x 238 mm (w x h x d, maximum including cable-glands and wall mounts)
  • Case material: Glass-fibre reinforced polyester, black
  • Surface resistance: < 109 Ω
  • Power supply: 21 V … 29 V DC
  • Relay outputs Switching voltage: 48 V DC / 32 V AC max. Switching current: 250 mA max. (resistive load)
  • Input: 1 x external reset (5 V DC)
  • Weight: 6 kg including cable-glands and wall mounts
  • Current draw: 80 mA (normal operation) / 100 mA (alarm) at 24 V DC
  • Power consumption: Max. 2,4 W
  • Relays: 1 fire alarm per sensor cable input, 1 common fault

Ordering information

  • Sensor Control Unit SCU 800-03-Ex

Scope of delivery

  • Sensor Control Unit SCU 800-03-Ex including four wall-mounts, screw plugs in housing bores, cable-glands in plastic bag
  • LISTmemory USB flash drive

SCU 800-03 (cat. D)

 

Features

  • Approved by DNV-GL, certificate-no.: 60 380 – 09 HH
  • Evaluation of temperatures measured by sensor cables SEC 15 and/or external sensors ESD
  • Two sensor cable inputs A and B
  • Alarm triggering via differential and maximum temperature evaluation
  • Response characteristic according to EN54-5, class A1, approved by VdS Schadenverhütung, VdS no.: G 205143
  • Intelligent evaluation algorithms prevent false alarms
  • Highly durable via utilisation of maintenance-free components, RoHS compliant
  • Alarm indication on unit front via LEDs
  • Low power consumption
  • Up to 64 programmable individual zones with alarm and fault status signalling to superordinate systems via protocol
  • One common fault relay and one fire alarm relay each per sensor cable input
  • Relay outputs configurable with loop resistors for closed-circuit monitoring
  • EMC approved cover gasket
  • Metric polyamide cable-glands with NBR O-Ring and seal

Front panel displays

  • Fire alarm: LED red (1x per Sensor cable input A and B)
  • Fault: LED orange
  • Operation: LED green
  • Measuring cycle: LED orange
  • Data Transmission: LED orange

System specifications

  • Operating temperature: -25 °C …+70 °C (0 °C … +40 °C approved by VdS)
  • Ingress protection: IP 65
  • Measurement resolution: 0,1 °C
  • Repeatability:  0,1 K
  • Sensor quantity: Up to 99 sensors per sensor cable input
  • Sensor cable length: Up to 250 m per sensor cable input including connection cable CC15

Connections and interfaces

  • K1 und K2: Sensor cable inputs
  • 24 V DC: Power supply
  • RS232: For unit parameterisation or connection to superordinate systems
  • RS485: Data interface for LIST Master/Slave network, or connection to superordinate systems, or unit parameterisation
  • Relay outputs: For fire alarms and common fault signalling
  • Reset: Galvanically isolated external reset input

Supported software protocols

  • MODBUS (RTU) via serial interface RS232 or RS485

General data

  • Dimensions: 326,0 x 179,0 x 91,0 mm (w x h x d, maximum including cable-glands)
  • Case material: Aluminium, powder coated in RAL 7040, grey
  • Power supply: 21 V … 29 V DC
  • Relay outputs: Switching voltage: 48 V DC / 32 V AC max. Switching current: 250 mA max. (resistive load)
  • Input: 1 x external reset (5 V DC)

SCU 800-03:

  • Weight: 1,95 kg, including cable-glands
  • Current draw: 80 mA (normal operation) / 100 mA (alarm) at 24 V DC
  • Power consumption: Max. 2,4 W
  • Relays: 1 x fire alarm per sensor cable input, 1 x common fault

Ordering information

  • Sensor Control Unit SCU 800-03 (cat.D)

Scope of delivery

  • Sensor Control Unit SCU 800-03 (cat. D) including metric cable glands and connection materials, LISTmemory USB flash drive

 

 

Universal Connection Module UCM 15

Posted in SEC 15 | Comments Off on Universal Connection Module UCM 15

Connection Box CBO 15

Posted in SEC 15 | Comments Off on Connection Box CBO 15

d-LIST controller d-LCON

Posted in SEC 15 | Comments Off on d-LIST controller d-LCON

Accessories

Posted in SEC 15 | Comments Off on Accessories

Connection Box CBO 5

Posted in SEC 15 | Comments Off on Connection Box CBO 5

Connection Cable

Posted in SEC 15 | Comments Off on Connection Cable

Connection Module

Posted in SEC 15 | Comments Off on Connection Module

External Sensors

Posted in SEC 15 | Comments Off on External Sensors

Power Supply

Posted in SEC 15 | Comments Off on Power Supply

Remote Display Unit

Posted in SEC 15 | Comments Off on Remote Display Unit

SEC 15 Simulator

Posted in SEC 15 | Comments Off on SEC 15 Simulator

Sensor Cable

Posted in SEC 15 | Comments Off on Sensor Cable

Sensor Control Unit

Posted in SEC 15 | Comments Off on Sensor Control Unit

Software

Posted in SEC 15 | Comments Off on Software