LAN CABLE Cat6 SF/UTP
Fire resistance EN 50200 PH120
Flame retardant IEC 60332-3-24 Cat. C
Acid gas emission EN 60754-1 EN 60754-2
Smoke density EN 61034-2
Fire Standards
Our ‘Standard’ and ’Enhanced’ Fire cables are manufactured in the European Union in accordance with British Standards BS7629-1, BS EN 50200 PH30 / PH60 / PH120, BS7846 and BS6387 CWZ PH120.
We do supply LPCB & BASEC certified cables.
For more information, please visit Fire Standards
Conductor | Solid plain annealed copper wire 22AWG/1 |
Insulation | Polyolefin with mica glass for fire resistance |
Cabling | The insulated cores are cabled together in 4 pairs |
Fire barrier | Glass Tape |
Overall shield | Copper drain wire/polyester tape/bare copper braid |
Outer Sheath | LSZH thermoplastic compound, red |
Nom. Outer diameter | 10.6mm |
Pair Capacitance | 65 pF/m |
Impedance | 100 Ohms +/-15% |
Fire resistance | EN 50200 PH120 (120min@840°C) |
Flame retardant | EN / IEC 60332-1-2 |
Corrosive acid gas ≤0.5% | EN / IEC 60754-1 EN / IEC 60754-2 |
Smoke density (LT ≥60%) | EN / IEC 61034-2 |
Max DC conductor resistance | 59,4 Ohms/km |
Max operating voltage | 125 Vac |
Min insulation resistance | 2,0 GOhms x km |
Velocity of propagation | 66% |
Delay skew | 20 nsec/100m |
Fire Alarm & Emergency Standard 300/500V
SR 114H – 300/500 V (solid)
Posted in Fire Performance Comments Off on Fire Alarm & Emergency Standard 300/500V Fire Alarm & Emergency Enhanced 300/500V
SR 114E – 300/500 V (solid)
Posted in Fire Performance Comments Off on Fire Alarm & Emergency Enhanced 300/500V Fire Resistant LAN 300/500V
FIRE RESISTANT LAN CABLE
CAT6 SF/UTP
Posted in Fire Performance Comments Off on Fire Resistant LAN 300/500V Data Enhanced 300/500V
Data Enhanced 300/500 V
Posted in Fire Performance Comments Off on Data Enhanced 300/500V Mineral Insulated Fire Performance
FIRECEL MI are intended to be installed in critical safety circuits which are used to operate under fire conditions in severe applications where the mechanical cables performances are primarily required.
Posted in Fire Performance Comments Off on Mineral Insulated Fire Performance Fibre Optic Fire Performance
SLO-000-**-M1-A1-FR
SLO-000-**-M1-A3-FR
SLO-000-**-M1-A5-FR
SLO-000-**-M1-A7-FR
Posted in Fire Performance Comments Off on Fibre Optic Fire Performance Single Core Fire Performance 450/750V
SR 112 – Single Core Mica/XLPE Insulation
SR 112X – Twin Core Mica/XLPE Insulation
R-mXLSZH 450/750 V (600/1000 V for protected installation)
Posted in Fire Performance Comments Off on Single Core Fire Performance 450/750V Fire Performance Mains Cable Standard 600/1000V
Fire performance cables maintain circuit integrity in a fire and so are suitable for fire detection, alarm and emergency lighting systems.
Posted in Fire Performance Comments Off on Fire Performance Mains Cable Standard 600/1000V Fire Performance Mains Cable Enhanced 600/1000V
BS7846 – F120 (Enhanced)
Posted in Fire Performance Comments Off on Fire Performance Mains Cable Enhanced 600/1000V