Cable Construction
| Conductor | Solid Copper Conductor |
| Insulation | PE (Polyethylene) |
| Filler | PE (Polyethylene) |
| Bedding | Mylar Shield |
| Rip Cord | Nylon |
| Sheath | PE (Polyethylene) |
Dimensions
| No. of Pairs | Nominal Diameter of Conductor mm | Nominal Thickness of Pair Insulation mm | Nominal Overall Diameter mm | Nominal Weight kg/km |
|---|
| 25 | 0.51 | 0.91 | 12 | 154.4 |
Performance Characteristics| Frequency MHz | Attenuation (-dB/100m)(±30%) | Next Worst Pair (dB/100m) | RL (dB/100m) |
|---|
| 1 | 2 | 52.24 | 16 |
| 4 | 4.1 | 45.04 | 18.4 |
| 8 | 5.8 | 41.44 | 19.6 |
| 10 | 6.5 | 40.24 | 20 |
| 16 | 8.2 | 37.84 | 20 |
| 20 | 9.3 | 36.64 | 20 |
| 25 | 10.4 | 35.44 | 19.44 |
| 31.25 | 11.7 | 34.32 | 18.88 |
| 62.5 | 17 | 30.72 | 17.2 |
| 100 | 22 | 28.24 | 16.08 |
Electrical Characteristics| Impedance (1-100MHz) ohms | Maximum DC Resistance of Conductor At 20ºC ohms/km |
|---|
| 100(±15) | 101.2 |