Cable Construction

ConductorClass 1 Solid Copper Conductor
InsulationSolid PE (Polyethylene)
ScreenAL-Foil (Aluminium Foil)
Drain WireTinned Copper
SheathLSZH (Low Smoke Zero Halogen)
BeddingLSZH (Low Smoke Zero Halogen)
BraidingGSWB (Galvanised Steel Wire Braid)

Dimensions

No. of Pairs (24 AWG)Nominal Thickness of Insulation mmNominal Overall Diameter mmNominal Weight kg/km
41.049.4124
Performance Characteristics
Frequency MHzAttenuation dB/100mNext dBRL dBElfext dBPS - Elfext dB/100mACR dB
1265.323.163.860.863
44.156.32351.748.751
85.851.824.545.742.745
106.550.32543.840.843
168.247.32539.736.737
20 9.345.82537.734.735
2510.2344.324.235.832.832
31.2511.7142.923.333.930.929
62.517.2538.420.727.824.819
1002235.319.2423.820.89
Electrical Characteristics
Impedance (1-100MHz) ohmsMaximum Resistance
of Conductor At 20ºC ohms/km
100±15101.2