Cable Construction
Conductor | Class 1 Solid Copper Conductor |
Insulation | Solid PE (Polyethylene) |
Screen | AL-Foil (Aluminium Foil) |
Drain Wire | Tinned Copper |
Sheath | LSZH (Low Smoke Zero Halogen) |
Bedding | LSZH (Low Smoke Zero Halogen) |
Braiding | GSWB (Galvanised Steel Wire Braid) |
Dimensions
No. of Pairs (24 AWG) | Nominal Thickness of Insulation mm | Nominal Overall Diameter mm | Nominal Weight kg/km |
---|
4 | 1.04 | 9.4 | 124 |
Performance CharacteristicsFrequency MHz | Attenuation dB/100m | Next dB | RL dB | Elfext dB | PS - Elfext dB/100m | ACR dB |
---|
1 | 2 | 65.3 | 23.1 | 63.8 | 60.8 | 63 |
4 | 4.1 | 56.3 | 23 | 51.7 | 48.7 | 51 |
8 | 5.8 | 51.8 | 24.5 | 45.7 | 42.7 | 45 |
10 | 6.5 | 50.3 | 25 | 43.8 | 40.8 | 43 |
16 | 8.2 | 47.3 | 25 | 39.7 | 36.7 | 37 |
20 | 9.3 | 45.8 | 25 | 37.7 | 34.7 | 35 |
25 | 10.23 | 44.3 | 24.2 | 35.8 | 32.8 | 32 |
31.25 | 11.71 | 42.9 | 23.3 | 33.9 | 30.9 | 29 |
62.5 | 17.25 | 38.4 | 20.7 | 27.8 | 24.8 | 19 |
100 | 22 | 35.3 | 19.24 | 23.8 | 20.8 | 9 |
Electrical CharacteristicsImpedance (1-100MHz) ohms | Maximum Resistance of Conductor At 20ºC ohms/km |
---|
100±15 | 101.2 |