Cable Construction
ConductorClass 2 stranded tinned conductor
InsulationEPR (Ethylene Propylene Rubber) Type GP4 according to BS 7655
SheathHDPCP (Heavy Duty Polychloroprene) Type RS2 according to BS 7655

Dimensions

Cable TypeNo. of CoresNominal Cross Sectional Area mm²Minimum Thickness of Sheath mmMinimum Overall Diameter mmMaximum Overall Diameter mmNominal Weight kg/km
B112.527.28.934
B111029.411.8205
B1135212.916.1495
B22129.913240
B221.529.412.1151
B222.5210.513.1187
B224213.216.3267
B221021518.7448
B2216216.720.9630
B22352.222.327.81520
B22702.428.8361904
B22952.633.241.52885
B2310217.320.7525
B2316219.823.2770
B240.75210.212.8173
B241.5210.913.7220
B242.5211.914.8264
B270.75211.814.7240
B271.5212.615.8305
B272.5213.817.2390
B2100.75214.418345
B2101.5215.619.4405
B2102.5217.121.3565
B2120.75214.818.5350
B2121.521620465
B2122.5217.622570
B2190.7521721.3490
B2191.5218.523.1649
B2192.5220.425.5886
B2270.75220.125.1640
B2271.52.222.227.8880
B2272.52.224.630.71225
B2370.752.222.728.4850
B2371.52.225.131.41190
B2372.52.427.834.71190
B2480.752.225.732.21650
B2481.52.428.135.11590
B2482.52.631.2391980
B26 x 20.75219.724.6465
B26 x 22.5223.729.6570

Class 2 Stranded Conductors for Single Core and Multi-Core Cables
Nominal Cross
Sectional Area mm²
Maximum No. Of Wires In ConductorMaximum Resistance
of Conductor At 20ºC
CircularCircular CompactedShapedAnnealed Copper Conductor
CuAlCuAlCuAlMetal-Coated Wires ohms/km
0.757-----24.8
17-----18.2
1.57-6---12.2
2.57-6---7.56
47-6---4.7
67-6---3.11
107766--1.84
167766--1.16
357766660.529
701919121212120.27
951919151515150.195

The above table is in accordance with BS EN 60228 (previously BS 6360)

 