Print Friendly, PDF & Email
Cable Construction
ConductorClass 5 tinned conductor
InsulationEPR (Ethylene Propylene Rubber) Type GP4 according to BS 7655
Screen (C3 only)AL (Aluminium Tape)
Drain WireType C3 only
SheathHDPCP (Heavy Duty Polychloroprene) Type RS2 according to BS 7655
BeddingPET (Polyethylene Terephthalate)

Dimensions

Cable TypeNo. of CoresNominal Cross Sectional Area mm²Minimum Thickness of Sheath mmMinimum Overall Diameter mmMaximum Overall Diameter mmNominal Weight kg/km
C112.53.811.214174
C222.53.814.918.8338
C242.53.816.420.9450
C272.53.818.723.7612
C2102.53.822.528.6836
C26 x 20.753.823.229.3868
C2122.53.823.229.3909
C2162.53.825.332985
C32+ Drain2.53.81520341

Class 5 Flexible Copper Conductors for Single Core and Multi-Core Cables
The below table is in accordance with BS EN 60228 (previously BS 6360)
Nominal Cross
Sectional Area mm²
Maximum Diameter of Wires in Conductor mmMaximum Resistance
of Conductor At 20ºC
Metal-Coated Wires ohms/km
0.750.426.7
2.50.268.21

The above table is in accordance with BS EN 60228 (previously BS 6360)

 

power-accessories01

Our power cables have many accessories.

For more information, don’t hesitate to call us on 0121 508 6890 or get in touch via our Contact Page.