Print Friendly, PDF & Email

Cable Construction

ConductorData Pair: Class 2 Stranded Tinned Copper - 24/19AWG (0.25mm²)
Power Pair: Class 2 Stranded Tinned Copper - 22/19AWG (0.35mm²)
InsulationPair 1 - Data: Foam-Skin PE (Polyethylene)
Pair 2 - Power: Solid PE (Polyethylene)
ShieldAL/PET (Aluminium / Polyester Tape)
Overall ShieldTCWB (Tinned Copper Wire Braid)
SheathFRNC-LSZH (Flame Retardant Non-Corrosive Low Smoke Zero Halogen)
Drain WireTinned Copper - 24AWG

Dimensions

Nominal Cross Sectional Area of Data Pair Conductor mm²Nominal Cross Sectional Area of Power Supply Pair Conductor mm²Nominal Coverage Metallic Braid %Nominal Diameter of Outer Sheath mmNominal Weight kg/km
0.250.35656.970
Electrical Characteristics at 20°C
DC Conductor Resistance
Ω/km
Capacitance at 800Hz Data Pair
pF/km
Impedance ≥ 1MHz Data Pair ΩAttenuation dB/kmDielectric Strength
kVac/1min
Minimum Insulation Resistance
GΩ x km
Transfer Impedance at 10MHz
mΩ/m
DataPower Supply Pairat 125kHzat 500kHzat 1MHz
7752401200.91.62.11.557