Communication, Network Cable, Bus Cable
Cable Construction
Conductor | Class 6 Stranded Tinned Copper Wires |
Insulation | TPE (Thermoplastic Elastomer) |
Sheath | TPE (Thermoplastic Elastomer) |
Dimensions
No. of Cores | Nominal Cross Sectional Area mm² | Nominal Insulation Diameter mm |
---|
2 | 1.5 | 2.5 |
Electrical Characteristics at 20°CMaximum Conductor Resistance mohms/m | Capacitance at 167kHz pF/m | Inductance at 167kHz nH/m | Impedance at 167kHz ohms |
---|
13.7 | 35 to 45 | 520 to 700 | 70 to 140 |
Communication, Network Cable, Bus Cable
Cable Construction
Conductor | Class 1 Solid Copper Conductor |
Insulation | LSZH (Low Smoke Zero Halogen) |
Bedding | LSZH (Low Smoke Zero Halogen) |
Screen 1 | AL/PET (Aluminium/Polyester Tape) |
Screen 2 | TCWB (Tinned Copper Wire Braid) |
Sheath | LSZH (Low Smoke Zero Halogen) |
Dimensions
No. of Pairs | Nominal Conductor Diameter mm² (AWG/Strands) | Nominal Insulation Diameter mm | Nominal Bedding Diameter mm | Nominal Overall Diameter | Nominal Weight kg/km |
---|
2 | 0.34 (22/1) | 1.43 | 4.2 | 6.5 | 74 |
Electrical CharacteristicsMaximum DC Conductor Resistance Ω/km | Capacitance pF/km | Minimum Insulation Resistance GΩ x km | Impedance Ω | Nominal Propagation Velocity % | Delay Skew ns/100m | Dielectric Strength kVac / 1 min |
---|
| Core/Core | Unbalanced | | | | | Core/Core | Unbalanced |
56.4 | 52 | 1600 | 5 | 100 | 67 | 50 | 1.5 | 1 |
Communication, Network Cable, Bus Cable
Cable Construction
Conductor | Solid Bare Copper Wire (18/1AWG) |
Insulation | Solid PE (Polyethylene) |
Bedding | PET (Polyester Tape) |
Filler | PET (Polyethylene Terephthalate) Fibres |
Shield | AL/PET (Aluminium / Polyester Tape) |
Sheath | PVC (Polyvinyl Chloride) |
Braid | TCWB (Tinned Copper Wire Braid) 60% Coverage |
Dimensions
No. of Pairs | Nominal Cross Sectional Area mm² | Nominal Conductor Diameter mm | Nominal Insulation Diameter mm | Nominal Outer Diameter of Filler Sheath mm | Nominal Diameter of Outer Sheath mm | Nominal Weight kg/km |
---|
1 | 0.85 | 1.04 | 2.5 | 5.5 | 7.6 | 89 |
Electrical Characteristics at 20°CMaximum DC Conductor Resistance Ω/km | Capacitance at 800Hz pF/km | Impedance (3÷20MHz) Ω (±10%) | Impedance Ω | Attenuation dB/km |
---|
| | | 31.25kHz | 39kHz | 1MHz | Maximum at 39kHz | Nominal at 100kHz | Nominal at 1MHz |
22 | 60 | 150 | 100 | 100 | 80 | 3 | 4 | 15 |
Inductance at 31.25KH mH/km | Dielectric Strength kVac / 1 min | Minimum Insulation Resistance GΩ x KM | Transfer Impedance mΩ/M | Maximum Installation Pulling N |
---|
| Conductor/Conductor | Conductor/Shield | | 100kHz | 1MHz | |
0.7 | 2.5 | 2.5 | 5 | 15 | 10 | 120 |
Communication, Network Cable, Bus Cable
Cable Construction
Conductor | Solid Bare Copper Wire (18/1AWG) |
Insulation | Solid PE (Polyethylene) |
Bedding | PET (Polyester Tape) |
Filler | Halogen Free Compound |
Shield | AL/PET (Aluminium / Polyester Tape) |
Sheath | FRNC LSZH (Low Smoke Zero Halogen) Compound |
Braid | TCWB (Tinned Copper Wire Braid) 60% Coverage |
Dimensions
No. of Pairs | Nominal Cross Sectional Area mm² | Nominal Conductor Diameter mm | Nominal Insulation Diameter mm | Nominal Outer Diameter of Filler Sheath mm | Nominal Diameter of Outer Sheath mm | Nominal Weight kg/km |
---|
1 | 0.85 | 1.04 | 2.5 | 5.5 | 7.6 | 89 |
Electrical Characteristics at 20°CMaximum DC Conductor Resistance Ω/km | Capacitance at 800Hz pF/km | Impedance (3÷20MHz) Ω (±10%) | Impedance Ω | Attenuation dB/km |
---|
| | | 31.25kHz | 39kHz | 1MHz | Maximum at 39kHz | Nominal at 100kHz | Nominal at 1MHz |
22 | 60 | 150 | 100 | 100 | 80 | 3 | 4 | 15 |
Inductance at 31.25 KH mH/km | Dielectric Strength kVac / 1 min | Minimum Insulation Resistance GΩ x KM | Transfer Impedance mΩ/M | Maximum Installation Pulling N |
---|
| Conductor/Conductor | Conductor/Shield | | 100kHz | 1MHz | |
0.7 | 2.5 | 2.5 | 5 | 15 | 10 | 120 |
Communication, Network Cable, Bus Cable
Cable ConstructionConductor | Solid Bare Copper Wire Conductor |
Insulation | LSZH (Low Smoke Zero Halogen) |
Tape | Plastic Foil |
Screen | Aluminium / Polyester Tape (AL/PET) |
Sheath | LSZH (Low Smoke Zero Halogen) |
Drain Wire | Tinned Copper Wire |
Dimensions
No. of Pairs | Diameter of Conductor mm | Nominal Overall Diameter mm | Nominal Weight kg/km |
---|
2 Pair (Quad) | 0.8 | 6.2 | 64 |
Electrical CharacteristicsMaximum (Conductor) Loop Resistance Ω/km | Maximum Insulation Resistance at 20°C MΩ x km | Maximum Capacitance Unbalance C, pF/100m | Maximum Mutual Capacitance nF/km |
---|
73.2 | 100 | 200 | 100 |
Communication, Network Cable, Bus Cable
Cable Construction
Conductor | Class 1 Solid Copper Conductor |
Insulation | Solid PE (Polyethylene) |
Bedding | PET (Polyester Tape) |
Filler | Halogen Free Compound |
Shield 1 | AL/PET (Aluminium/Polyester Tape) |
Shield 2 | TCWB (Tinned Copper Wire Braid) |
Inner Sheath | FRNC-LSZH (Flame Retardant Non Corrosive - Low Smoke Zero Halogen) |
Armour | GSWB (Galvanized Steel Wire Braid) |
Outer Sheath | FRNC-LSZH (Flame Retardant Non Corrosive - Low Smoke Zero Halogen) |
Dimensions
No. of Pairs | Diameter of Conductor mm | Nominal Overall Diameter mm | Nominal Weight kg/km |
---|
1 | 0.85 | 11 | 190 |
Electrical and Transmission Properties at 20°CMaximum DC Resistance of Conductor | 22ohms/km |
Capacitance at 800Hz | 60nF/km |
Impedance at 1Mhz | 80ohms (±10%) |
Impedance 31.25kHz | 100ohms (±10%) |
Impedance at 39khz | 100ohms (±10%) |
Impedance (3/20Mhz) | 150ohms (±10%) |
Inductance at 31.25kHz | 0.7mH/km |
Nominal Attenuation at 1MHz | 15dB/km |
Maximum Attenuation at 39kHz | 3dB/km |
Nominal Attenuation at 100kHz | 4dB/km |
Maximum Propagation Delay Change (7.9/39kHz) | 1.7µsec/km |
Dielectric Strength (Conductor/Conductor) | 2.5kVac/1min |
Dielectric Strength (Conductor/Shield) | 2.5kVac/1min |
Minimum Insulation Resistance | 5Gohms/km |
Transfer Impedance at 100kHz | 15mohms/km |
Transfer Impedance at 1MHz | 10mohms/km |
Communication, Network Cable, Bus Cable
Cable Construction
Conductor | Class 1 Solid Copper Conductor |
Insulation | Foam-Skin PE (Polyethylene) |
Bedding | PET (Polyester Tape) |
Filler | HFFR (Halogen Free Flame Retardant) Compound |
Shield 1 | AL/PET (Aluminium/Polyester Tape) |
Shield 2 | TCWB (Tinned Copper Wire Braid) |
Inner Sheath | FRNC-LSZH (Flame Retardant Non Corrosive - Low Smoke Zero Halogen) |
Armour | GSWB (Galvanized Steel Wire Braid) |
Outer Sheath | FRNC-LSZH (Flame Retardant Non Corrosive - Low Smoke Zero Halogen) |
Dimensions
No. of Pairs | Diameter of Conductor mm | Nominal Overall Diameter mm | Nominal Weight kg/km |
---|
1 | 0.64 | 11.2 | 175 |
Electrical and Transmission Properties at 20°CMaximum DC Resistance of Conductor | 57.5ohms/km |
Capacitance at 800Hz | 29nF/km |
Impedance (above 1Mhz) | 150ohms (±10%) |
Attenuation at 9.6kHz | 0.3dB/100m |
Attenuation at 38.4kHz | 0.5dB/100m |
Attenuation at 4MHz | 2.1dB/100m |
Attenuation at 16MHz | 4dB/100m |
Dielectric Strength (Conductor/Conductor) | 1.5kVac/1min |
Dielectric Strength (Conductor/Shield) | 1.5kVac/1min |
Minimum Insulation Resistance | 5Gohms/km |
Transfer Impedance at 10MHz | 10mohms/m |
Communication, Network Cable, Bus Cable
Cable Construction
Conductor | Stranded Copper Conductor |
Insulation | Solid PE (Polyethylene) |
Bedding | PET (Polyester Tape) |
Inner Sheath | Halogen Free Material |
Shield | AL/PET (Aluminium / Polyester Tape) |
Overall Shield | TCWB (Tinned Copper Wire Braid) |
Outer Sheath | HFFR (Halogen Free Flame Retardant) PUR Compound |
Dimensions
No. of Cores | Nominal Overall Diameter mm | Nominal Weight kg/km |
---|
4 | 6.6 | 70 |
Electrical and Transmission Properties at 20°CMaximum DC Resistance of Conductor | 55ohms/km |
Maximum Resistance Unbalance | 3% |
Mutual Capacitance at 1kHz | 52nF/km |
Maximum Capacitance Unbalance | 1600pF/km |
Nominal Velocity of Propagation at 100MHz | 67% |
Characteristic Impedance | 100ohms (±15ohms) |
Maximum Propagation Delay at 100MHz | 510nsec/100m |
Maximum Delay Skew at 100MHz | 10nsec/100m |
Minimum Insulation Resistance | 5Gohms/km |
Transfer Impedance at 100kHz | 15mohms/m |
Transfer Impedance at 1MHz | 10mohms/m |
Transfer Impedance at 10MHz | 12mohms/m |
Transfer Impedance at 30MHz | 50mohms/m |
Transfer Impedance at 100MHz | 250mohms/m |
Screening Attenuation | Above 60dB |
Coupling Attenuation | Above 50dB |
Frequency MHz | Attenuation dB/100m | Next dB | El-Fext dB/100m | ACR dB/100m | RL dB |
---|
| Standard Maximum | Typical | Standard Maximum | Typical | Standard Maximum | Typical | Standard Maximum | Typical | Standard Maximum | Typical |
1 | 2.1 | 1.7 | 65.3 | 85 | N/A | 85 | 63.2 | 83.3 | - | 30 |
4 | 4 | 3.4 | 56.3 | 75 | 51.8 | 77 | 52.3 | 71.6 | 24.1 | 32 |
10 | 6.3 | 5.5 | 50.3 | 68 | 43.8 | 66 | 44 | 62.5 | 25 | 36 |
16 | 8 | 7.2 | 47.2 | 64 | 39.7 | 59 | 39.2 | 56.8 | 25 | 36 |
20 | 9 | 8.2 | 45.8 | 62 | 37.8 | 56 | 36.8 | 53.8 | 25 | 36 |
31.25 | 11.4 | 10.5 | 42.9 | 60 | 33.9 | 48 | 31.5 | 49.5 | 23.6 | 34 |
62.5 | 16.5 | 15.4 | 38.4 | 52 | 27.9 | 40 | 21.9 | 36.6 | 21.5 | 30 |
100 | 21.3 | 20 | 35.3 | 48 | 23.8 | 36 | 14 | 28 | 20.1 | 26 |
Communication, Network Cable, Bus Cable
Cable Construction
Conductor | Solid Bare Copper Wire - 22/1AWG |
Insulation | Foam-Skin Polyethylene |
Bedding | PET (Polyester Tape) |
Inner Sheath | PVC (Polyvinyl Chloride) |
Shield | AL/PET (Aluminium / Polyester Tape) |
Sheath | PVC (Polyvinyl Chloride) |
Braid | Tinned Copper Wires, 60% Coverage |
Dimensions
No. of Pairs | Nominal Cross Sectional Area mm² | Nominal Conductor Diameter mm | Nominal Insulation Diameter mm | Nominal Outer Diameter of Inner Sheath mm | Nominal Diameter of Outer Sheath mm | Nominal Weight kg/km |
---|
1 | 0.35 | 0.64 | 2.5 | 5.5 | 7.9 | 76 |
Electrical Characteristics at 20°CMax DC Loop Conductor Resistance Ω/km | Maximum DC Conductor Resistance Ω/km | Capacitance at 800Hz pF/km | Impedance (3÷20MHz) Ω(±10%) | Maximum Attenuation dB/km |
---|
| | | | 9.6kHz | 38.4kHz | 4kHz | 16kHz |
115 | 57.5 | 29 | 150 | 0.3 | 0.5 | 2.1 | 4 |
Dielectric Strength kVac / 1 min | Minimum Insulation Resistance GΩ x KM | Maximum Installation Pulling N |
---|
Conductor/Conductor | Conductor/Shield | | |
1.5 | 1.5 | 5 | 100 |
Communication, Network Cable, Bus Cable
Cable Construction
Conductor | Solid Bare Copper Wire - 22/1AWG |
Insulation | Foam-Skin Polyethylene |
Bedding | PET (Polyester Tape) |
Inner Sheath | Flame Retardant Halogen Free Compound |
Shield | AL/PET (Aluminium / Polyester Tape) |
Sheath | FRNC-LSZH (Flame Retardant Non-Corrosive Low Smoke Zero Halogen) Compound |
Braid | Tinned Copper Wires, 60% Coverage |
Dimensions
No. of Pairs | Nominal Cross Sectional Area mm² | Nominal Conductor Diameter mm | Nominal Insulation Diameter mm | Nominal Outer Diameter of Inner Sheath mm | Nominal Diameter of Outer Sheath mm | Nominal Weight kg/km |
---|
1 | 0.35 | 0.64 | 2.5 | 5.5 | 7.9 | 76 |
Electrical Characteristics at 20°CMax DC Loop Conductor Resistance Ω/km | Maximum DC Conductor Resistance Ω/km | Capacitance at 800Hz pF/km | Impedance (3÷20MHz) Ω(±10%) | Maximum Attenuation dB/km |
---|
| | | | 9.6kHz | 38.4kHz | 4kHz | 16kHz |
115 | 57.5 | 29 | 150 | 0.3 | 0.5 | 2.1 | 4 |
Dielectric Strength kVac / 1 min | Minimum Insulation Resistance GΩ x KM | Maximum Installation Pulling N |
---|
Conductor/Conductor | Conductor/Shield | | |
1.5 | 1.5 | 5 | 100 |
Communication, Network Cable, Bus Cable
Cable Construction
Conductor | Data Pair: Stranded Tinned Copper Wires - 18/19AWG (0.25mm²) Power Supply Pair: Stranded Tinned Copper Wires - 15/19AWG (0.35mm²) |
Insulation | Data Pair: Foam-Skin Polyethylene Power Supply Pair: Solid Polyethylene |
Bedding | PET (Polyester Tape) |
Individual Pair Shield | AL/PET (Aluminium / Polyester Tape) |
Overall Shield | TCWB (Tinned Copper Wire Braid) |
Sheath | FRNC-LSZH (Flame Retardant Non-Corrosive Low Smoke Zero Halogen) Compound |
Drain Wire | Tinned Copper |
Dimensions
Nominal Cross Sectional Area of Data Pair Conductor mm² | Nominal Cross Sectional Area of Power Supply Pair Conductor mm² | Nominal Coverage of Wire Braid % | Nominal Diameter of Outer Sheath mm | Nominal Weight kg/km |
---|
0.93 | 1.93 | 65 | 11.9 | 220 |
Electrical Characteristics at 20°CDC Conductor Resistance Ω/km | Capacitance at 800Hz Data Pair pF/km | Impedance ≥ 1MHz Data Pair Ω | Attenuation dB/km | Dielectric Strength kVac/1min | Minimum Insulation Resistance GΩ x km | Transfer Impedance at 10MHz mΩ/m |
---|
Data | Power Supply Pair | | | at 125kHz | at 500kHz | at 1MHz | | | |
23.2 | 11.3 | 40 | 120 | 0.4 | 0.8 | 1.25 | 2 | 5 | 15 |
Communication, Network Cable, Bus Cable
Cable Construction
Conductor | Data Pair: Class 2 Stranded Tinned Copper - 24/19AWG (0.25mm²) Power Pair: Class 2 Stranded Tinned Copper - 22/19AWG (0.35mm²) |
Insulation | Pair 1 - Data: Foam-Skin PE (Polyethylene) Pair 2 - Power: Solid PE (Polyethylene) |
Shield | AL/PET (Aluminium / Polyester Tape) |
Overall Shield | TCWB (Tinned Copper Wire Braid) |
Sheath | FRNC-LSZH (Flame Retardant Non-Corrosive Low Smoke Zero Halogen) |
Drain Wire | Tinned Copper - 24AWG |
Dimensions
Nominal Cross Sectional Area of Data Pair Conductor mm² | Nominal Cross Sectional Area of Power Supply Pair Conductor mm² | Nominal Coverage Metallic Braid % | Nominal Diameter of Outer Sheath mm | Nominal Weight kg/km |
---|
0.25 | 0.35 | 65 | 6.9 | 70 |
Electrical Characteristics at 20°CDC Conductor Resistance Ω/km | Capacitance at 800Hz Data Pair pF/km | Impedance ≥ 1MHz Data Pair Ω | Attenuation dB/km | Dielectric Strength kVac/1min | Minimum Insulation Resistance GΩ x km | Transfer Impedance at 10MHz mΩ/m |
---|
Data | Power Supply Pair | | | at 125kHz | at 500kHz | at 1MHz | | | |
77 | 52 | 40 | 120 | 0.9 | 1.6 | 2.1 | 1.5 | 5 | 7 |