Sensor specifications

  • Measurement range: -40 °C … +200 °C
  • Measurement resolution: 0,1 °C
  • Repeatability: 0,1 K
  • Supply voltage: 5 V DC via LIST controller

Ordering information

  • Sensor Cable SEC 20/01 (1 m sensor spacing)
  • Sensor Cable SEC 20/02 (2 m sensor spacing)
  • Sensor Cable SEC 20/03 (3 m sensor spacing)
  • Sensor Cable SEC 20/04 (4 m sensor spacing)
  • Sensor Cable SEC 20/05 (5 m sensor spacing)
  • Sensor Cable SEC 20/06 (6 m sensor spacing)
  • Sensor Cable SEC 20/08 (8 m sensor spacing)
  • Sensor Cable SEC 20/xx (Customer specified sensor spacing, limited to not less than 0,5 m)
  • ATEX marking for sensor cable SEC 20 (to be ordered for every separate sensor cable section)

Sensor Cable SEC 20-Ex

 

Features

  • ATEX marking for use in zones 2 and 22
  • Complete encapsulation to protect sensors from environmental influences
  • Sensor spacing selectable to comply to project demand
  • Pinpoint sensor location via individual addresses
  • Maintenance free cable
  • Aramid fibres serve as strain relief and as reinforcement in case of fire
  • Easy mounting by use of diverse fasteners
  • Branching of cable routes via connection boxes
  • To be used with sensor control unit LIST controller
  • May be combined with LIST external sensors ESA
  • Up to 3.200 m combined cable length, respectively up to 320 sensors per LIST controller

General data

  • Type of protection zone 2: Ex II 3G Ex nA IIC T4 Gc
  • Operating temp. zone 2: -20 °C … +80 °C, from 70 °C protected from mechanical impact energy (EN 60079-0 / 26.4.2)
  • Type of protection zone 22: Ex II 3D Ex tc IIIC T125 °C Dc
  • Operating temp. zone 22: -20 °C … +70 °C
  • Cable diameter: Typ. 18 mm
  • Flat conductor resistance: Typ. 85 Ω / km (single conductor)
  • Sheath material: HM4 mixture, halogen-free and flame retardant, according to EN 50267-2-1:1999-04,EN50267-2-2:1999-04, EN 60332-1-2:2005-06, EN 60332-2-2:2005-06, EN 61034-2:2006-03, IEC 60754-1, IEC 60754-2
  • Weight: Typ. 0,45 kg / m
  • Sheath colour: Grey or black
  • Marking: Consecutive number printed at each sensor location, followed by cable identifier
  • Deliverable cable length: Up to 2.000 m, prefabricated cable sections on request
  • Mounting temperature: ≥ +10 °C
  • Bending radius: ≥ 30 cm
  • Verified and approved to: FprEN 54-22:2012 by VdS Schadenverhutung, VdS no.: G 213072 Meets requirements of environmental classification III
Scope of delivery

  • Ordered sensor cable length may be shipped as a cable ring in a carton, on a one way drum, or on loaner KTG-drum and pallet
  • ATEX markings for every separate sensor cable section

Cable construction

  • Four-core flexible flat cable with temperature sensors
  • Filler material with strain relief
  • Aluminium foil shield
  • Sheath with imprints at each sensor location

Cable Imprint sec 20 imprint

  • Imprint 1: The sensor marking is used in cable lists, delivery notes etc.
  • Imprint 2: Static marking only

Accessories

Posted in SEC 20 | Comments Off on Accessories

Cabinets

Posted in SEC 20 | Comments Off on Cabinets

Connection Cable

Posted in SEC 20 | Comments Off on Connection Cable

Connection Box

Posted in SEC 20 | Comments Off on Connection Box

Connection Module

Posted in SEC 20 | Comments Off on Connection Module

Data Management Unit

Posted in SEC 20 | Comments Off on Data Management Unit

Ethernet-Switch

Posted in SEC 20 | Comments Off on Ethernet-Switch

External Sensors

Posted in SEC 20 | Comments Off on External Sensors

LIST cable tester

Posted in SEC 20 | Comments Off on LIST cable tester

LIST controller

Posted in SEC 20 | Comments Off on LIST controller

Power Supply

Posted in SEC 20 | Comments Off on Power Supply

Relay Module

Posted in SEC 20 | Comments Off on Relay Module

SEC 20 Simulator

Posted in SEC 20 | Comments Off on SEC 20 Simulator

Sensor Cable

Posted in SEC 20 | Comments Off on Sensor Cable

Software

Posted in SEC 20 | Comments Off on Software