SLO-000-**-M1-A1-FR
SLO-000-**-M1-A3-FR
SLO-000-**-M1-A5-FR
SLO-000-**-M1-A7-FR
These fire resistant, loose buffered, single tube, cables are mainly used inside buildings, tunnels or closed areas in general, are designed and manufactured to guarantee the signal transmission even in case of fire, thus safeguarding the operation of the safety systems or of particularly critical connections.
Cable Uses
Fire Standards
Our ‘Standard’ and ’Enhanced’ Fire cables are manufactured in the European Union in accordance with British Standards BS7629-1, BS EN 50200 PH30 / PH60 / PH120, BS7846 and BS6387 CWZ PH120.
We do supply LPCB & BASEC certified cables.
For more information please visit Fire Standards

Fibres | Singlemode and multimode fibres with loose technology coating. |
Structure | For type SLO-FR the jelly containing the fibres is reinforced with glass yarns and is wound with a flame resistant tape. For type MLO-FR the jelly filled tubes containing the fibres are individually wound with a mica tape and are cabled around a central steel or FRP (fibreglass reinforced plastic) element. When necessary glass yarn is the traction element. A flame resistant tape improves fire resistance. |
Operating temperatures | -40°C to +90°C |
Basic design | BS 7211 |
Fire resistant | BS 6387 (cat.C-W-Z tested in steel conduit) |
Acid gas Emission | EN 50267-2-1 / IEC 60754-1 EN 50267-2-2 / IEC 60754-2 |
Smoke density | EN 61034-2 / IEC 61034-2 |
A3 Metallic armoured
Type | Fibre (n°) | Tube Diameter (mm) | Diameter (mm) | Weight (kg/km) | Tension load (N) | Crush (N/100mm) |
---|---|---|---|---|---|---|
SLO-000-**-M1-A3-FR | 02 ÷ 12 | 2.7 | 9.0 | 100 | 2000 | 4000 |
SLO-000-**-M1-A3-FR | 16 ÷ 24 | 3.5 | 10.0 | 120 | 2000 | 4000 |
A5 Dielectric Armoured
Type | Fibre (n°) | Tube Diameter (mm) | Diameter (mm) | Weight (kg/km) | Tension load (N) | Crush (N/100mm) |
---|---|---|---|---|---|---|
SLO-000-**-M1-A5-FR | 02 ÷ 12 | 2.7 | 7.5 | 70 | 1500 | 3000 |
SLO-000-**-M1-A5-FR | 16 ÷ 24 | 3.5 | 8.0 | 80 | 1500 | 3000 |
A7 Metallic armoured
Type | Fibre (n°) | Tube Diameter (mm) | Diameter (mm) | Weight (kg/km) | Tension load (N) | Crush (N/100mm) |
---|---|---|---|---|---|---|
SLO-000-**-M1-A7-FR | 02 ÷ 12 | 2.7 | 10.5 | 180 | 2500 | 4000 |
SLO-000-**-M1-A7-FR | 16 ÷ 24 | 3.5 | 11.0 | 210 | 2500 | 4000 |
Fire Alarm & Emergency Standard 300/500V
SR 114H – 300/500 V (solid)
Posted in Fire Performance Comments Off on Fire Alarm & Emergency Standard 300/500V Fire Alarm & Emergency Enhanced 300/500V
SR 114E – 300/500 V (solid)
Posted in Fire Performance Comments Off on Fire Alarm & Emergency Enhanced 300/500V Fire Resistant LAN 300/500V
FIRE RESISTANT LAN CABLE
CAT6 SF/UTP
Posted in Fire Performance Comments Off on Fire Resistant LAN 300/500V Data Enhanced 300/500V
Data Enhanced 300/500 V
Posted in Fire Performance Comments Off on Data Enhanced 300/500V Mineral Insulated Fire Performance
FIRECEL MI are intended to be installed in critical safety circuits which are used to operate under fire conditions in severe applications where the mechanical cables performances are primarily required.
Posted in Fire Performance Comments Off on Mineral Insulated Fire Performance Fibre Optic Fire Performance
SLO-000-**-M1-A1-FR
SLO-000-**-M1-A3-FR
SLO-000-**-M1-A5-FR
SLO-000-**-M1-A7-FR
Posted in Fire Performance Comments Off on Fibre Optic Fire Performance Single Core Fire Performance 450/750V
SR 112 – Single Core Mica/XLPE Insulation
SR 112X – Twin Core Mica/XLPE Insulation
R-mXLSZH 450/750 V (600/1000 V for protected installation)
Posted in Fire Performance Comments Off on Single Core Fire Performance 450/750V Fire Performance Mains Cable Standard 600/1000V
Fire performance cables maintain circuit integrity in a fire and so are suitable for fire detection, alarm and emergency lighting systems.
Posted in Fire Performance Comments Off on Fire Performance Mains Cable Standard 600/1000V Fire Performance Mains Cable Enhanced 600/1000V
BS7846 – F120 (Enhanced)